                  5

41I-ACC

C.  Negative Pressure 

Negative pressure results from the imbalance of air avail-

able for the appliance to operate properly. It can be stron-

gest in lower levels of the house.

Causes include:

•  Exhaust fans (kitchen, bath, etc.)
•  Range hoods
•  Combustion air requirements for furnaces, water heaters 

and other combustion appliances

•  Clothes dryers
•  Location of return-air vents to furnace or air conditioning
•  Imbalances of the HVAC air handling system
•  Upper level air leaks such as: 

  -  Recessed lighting
  -  Attic hatch
  -  Duct leaks

To minimize the effects of negative air pressure:

•  Install the outside air kit with the intake facing prevailing 

winds during the heating season

•  Ensure adequate outdoor air for 

all combustion appliances 

and exhaust equipment

•  Ensure furnace and air conditioning return vents are not 

located in the immediate vicinity of the appliance

•  Avoid installing the appliance near doors, walkways or 

small isolated spaces

•  Recessed lighting should be a “sealed can” design
•  Attic hatches weather stripped or sealed
•  Attic mounted duct work and air handler joints and seams 

taped or sealed

•  Basement installations should be avoided 

D.  Tools And Supplies Needed 

Before beginning the installation be sure the following tools 

and building supplies are available:

Reciprocating saw 

Framing material

Pliers 

High temp caulking material

Hammer 

Gloves

Phillips screwdriver 

Framing square

Flat blade screwdriver  Electric drill and bits
Plumb line 

Safety glasses

Level 

Tape measure

Misc. screws and nails

1/2-3/4 in. length, #6 or #8 self-drilling screws

E. Inspect Appliance and Components

•  Remove appliance and components from packaging and 

inspect for damage.

•  Vent  system  components  and  doors  are  shipped  in 

separate packages.

•  Report to your dealer any parts damaged in shipment.

•  Read all the instructions before starting the installation. 

Follow these instructions carefully during the 

installation to ensure maximum safety and benefit.

Inspect appliance and components for damage. 

Damaged parts may impair safe operation.

WARNING

•  Do NOT install damaged components.

•  Do NOT install incomplete components.

•  Do NOT install substitute components.

Report damaged parts to dealer.

Fire Risk.

WARNING

•  Negative pressure can cause spillage of combus

-

tion fumes, soot and carbon monoxide.

•  Appliance needs to draft properly for safety.

Asphyxiation Risk.

Summary of Contents for 41I-ACC

Page 1: ...liance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may...

Page 2: ...es Needed 5 E Inspect Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances A Appliance Dimensions 7 B Clearances to Combustibles 8 C Alternate Floor Protection Calculation 9 D...

Page 3: ...ed trademark of Hearth Home Technologies Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and...

Page 4: ...national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION WARNING DO NOT...

Page 5: ...ir handler joints and seams taped or sealed Basement installations should be avoided D Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are...

Page 6: ...ght requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 8 Combustible materials not installed in non combustible areas Verified all clearances mee...

Page 7: ...ound w Cast STD 45 in 1143mm 31 in 787mm Metal Surround w Cast Trim REG 48 in 1219mm 34 in 864mm Metal Surround w Standard Trim STD 43 in 1092mm 31 in 787mm Metal Surround w Standard Trim LRG 51 in 12...

Page 8: ...6 inch 152mm S635 flue liner required as per ULC S628 In USA a minimum 5 ft length 1 82m 6 inch 152mm diameter flue liner is required as per UL 1482 SIDE TRIM SIDE WALL TOP TRIM 22 5 8 575mm 32 1 8 81...

Page 9: ...r k value The HIGHER the R factor means less heat is being conducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then...

Page 10: ...rough the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the...

Page 11: ...Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimne...

Page 12: ...cleaning and re installation When possible install an airtight clean out door to the rear of the smoke shelf A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be...

Page 13: ...ordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Masonry Chimney Cont d This insert confo...

Page 14: ...ue collar and the chimney top The air flow of the factory built zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing...

Page 15: ...lace opening the portion of the insert extending onto the hearth must be supported Manufacturer designed adjustable support kit can be ordered from your dealer Final approval of this installation type...

Page 16: ...ly Chimney heights exceeding 25 feet 7 62m from base of appliance may create an over draft situation Overdraft condition may create over firing Over firing may ignite creosote and or damage appliance...

Page 17: ...tion WARNING Option One Installation Instructions The outside air cover comes packaged with the component pack It is necessary to remove the blower housing and block off the room air with the outside...

Page 18: ...gure 18 1 2 Attach gasket to bottom side of flue collar with a thin coat of silicone C Leveling Legs 1 Remove the 2 screws already installed on each leg 2 Move legs to the desired height 3 Re install...

Page 19: ...w driver attach the side sur rounds to the top surround using 2 8 sheet metal screws provided with the kit Figure 19 1 3 Lay the trim face down and place the corner brackets into position 4 Using a st...

Page 20: ...0 1 3 Using phillips head screw driver remove snap disc bracket and cord restraint bracket from right side Figure 20 2 4 Re install snap disc bracket and cord restraint bracket to left side of blower...

Page 21: ...eet metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to...

Page 22: ...from each side of insert and use plumbers tape to secure to structure a washer may be required Re install bolts 3 Unit must be grounded with 8 solid copper grounding wire or equivalent and terminated...

Page 23: ...ludes Door Trim Spring Handle Hinge Pins And Logo Gold 41IDRTRIM GD Nickel 41IDRTRIM NL D T S C C A I 1 4 P S y l e t a r e p e S t i K m i r T r e d r O 1 3 X 3 4 d n u o r r u S Surround Trim Kit 43...

Page 24: ...mportant operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and opera...

Reviews: