Quadra-Fire 41I-ACC User Manual Download Page 21

October 14, 2013 

 

 

 

           7045-910 

 

 

 

         

                  21

41I-ACC

DOUBLE-SIDED

T

APE

DOUBLE-SIDED

T

APE

SCREWS ARE CIRCLED

EXPLODED VIEW OF SCISSORS

Figure 21.1

Thermal 

Protection

Decorative tile may 

be installed

INSTALL FRONT TRIM LAST.

CORNERS OVERLAP SIDE 

TRIM PIECES

EXPAND SCISSORS TO DESIRED HEIGHT

CUT TOP EDGE OF TRIM, 

NOT BOTTOM EDGE

Figure 21.2

Figure 21.3

Figure 21.4

Part No.  841-0990, size 9” x 45” and 

Part No. ADJSPT-12, size 12” x 50”

G.  Zero Clearance Adjustable Trim Support,  

     2” to 10” 

Included in Kit: (

1)  Trim  Top,  (1)  Trim  Front,  (2)  Trim 

Sides, Double-Sided Tape (already installed)

Tools Needed: 

 

Phillips  Head  Screwdriver,  Sheet  Metal 

Shears, Measuring Tape, Gloves

1. The  10  screws  on  each  set  of  scissors  will  already  be 

loose when shipped.  

Figure 21.1.

2.    Expand  scissors  to  desired  height.   Tighten  screws  to 

hold  in  place  using  Phillips  Head  screwdriver. 

Figure 

21.2.

3.  Measure front and side trims to required height to cover  

scissors and mark pieces for cutting.  Cut excess mate-

rial from top

 of trims edge, not  bottom.  This edge will 

be sharp; wear gloves to prevent injury to your hands.  

Figure 21.2.

4.  Using sheet metal shears, cut trim along the marked 

edge.  The cut edge fits under lip of top trim, so it allows 

for some variance in your straight edge.  

5. The double-sided tape that holds front and side trims to  

scissors has a particularly powerful bonding adhesive.  

Adjustments are extremely difficult once trim has adhered 

to tape.  Do a dry run first without removing paper from 

tape.

6.  Place cut edge of trim under top lip and into position on 

scissors.  Place side pieces on first and then front piece.  

The front piece overlaps side pieces. 

 

NOTE:  The trim in 

the Flush Mount Kit is one piece.

7.  Once you are satisfied with the positioning, remove trim 

and set aside.

8.  Remove the paper from double-sided tape that is to 

accept trim side.  Align side and then press hard against 

tape to secure side piece.  Repeat for other side.  Install 

front trim piece last.

9.  

There are 3 holes in the back flange of the top to secure it 

to the wall if necessary.  Use the appropriate fastener for 

the type of wall material, i.e., brick, sheetrock, etc.

 

NOTE:  3/8” ( 9.5mm) 

thick tile or like material can be cut 

to size and fit under lip of  top trim edge for a decorative 

touch.  

Figure 21.3.

10. Thermal protection of 1-1/2 inches (38mm), “k” value of 0.49 

and R value of 3.06 under the zero-clearance trim support.  

Figure 21.4.

Summary of Contents for 41I-ACC

Page 1: ...liance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may...

Page 2: ...es Needed 5 E Inspect Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances A Appliance Dimensions 7 B Clearances to Combustibles 8 C Alternate Floor Protection Calculation 9 D...

Page 3: ...ed trademark of Hearth Home Technologies Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and...

Page 4: ...national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION WARNING DO NOT...

Page 5: ...ir handler joints and seams taped or sealed Basement installations should be avoided D Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are...

Page 6: ...ght requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 8 Combustible materials not installed in non combustible areas Verified all clearances mee...

Page 7: ...ound w Cast STD 45 in 1143mm 31 in 787mm Metal Surround w Cast Trim REG 48 in 1219mm 34 in 864mm Metal Surround w Standard Trim STD 43 in 1092mm 31 in 787mm Metal Surround w Standard Trim LRG 51 in 12...

Page 8: ...6 inch 152mm S635 flue liner required as per ULC S628 In USA a minimum 5 ft length 1 82m 6 inch 152mm diameter flue liner is required as per UL 1482 SIDE TRIM SIDE WALL TOP TRIM 22 5 8 575mm 32 1 8 81...

Page 9: ...r k value The HIGHER the R factor means less heat is being conducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then...

Page 10: ...rough the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the...

Page 11: ...Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimne...

Page 12: ...cleaning and re installation When possible install an airtight clean out door to the rear of the smoke shelf A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be...

Page 13: ...ordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Masonry Chimney Cont d This insert confo...

Page 14: ...ue collar and the chimney top The air flow of the factory built zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing...

Page 15: ...lace opening the portion of the insert extending onto the hearth must be supported Manufacturer designed adjustable support kit can be ordered from your dealer Final approval of this installation type...

Page 16: ...ly Chimney heights exceeding 25 feet 7 62m from base of appliance may create an over draft situation Overdraft condition may create over firing Over firing may ignite creosote and or damage appliance...

Page 17: ...tion WARNING Option One Installation Instructions The outside air cover comes packaged with the component pack It is necessary to remove the blower housing and block off the room air with the outside...

Page 18: ...gure 18 1 2 Attach gasket to bottom side of flue collar with a thin coat of silicone C Leveling Legs 1 Remove the 2 screws already installed on each leg 2 Move legs to the desired height 3 Re install...

Page 19: ...w driver attach the side sur rounds to the top surround using 2 8 sheet metal screws provided with the kit Figure 19 1 3 Lay the trim face down and place the corner brackets into position 4 Using a st...

Page 20: ...0 1 3 Using phillips head screw driver remove snap disc bracket and cord restraint bracket from right side Figure 20 2 4 Re install snap disc bracket and cord restraint bracket to left side of blower...

Page 21: ...eet metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to...

Page 22: ...from each side of insert and use plumbers tape to secure to structure a washer may be required Re install bolts 3 Unit must be grounded with 8 solid copper grounding wire or equivalent and terminated...

Page 23: ...ludes Door Trim Spring Handle Hinge Pins And Logo Gold 41IDRTRIM GD Nickel 41IDRTRIM NL D T S C C A I 1 4 P S y l e t a r e p e S t i K m i r T r e d r O 1 3 X 3 4 d n u o r r u S Surround Trim Kit 43...

Page 24: ...mportant operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and opera...

Reviews: