CAI-QMINP-01 - QMini Plug Connector Customer Assembly Instructions
Document:
CAI-QMINP-01
Revision:
14
Release Date:
12/08/2014
Revision Date:
10/14/2019
QPC Fiber Optic, LLC
www.qpcfiber.com
27612 El Lazo Road, Laguna Niguel, CA 92677
Ph: (949) 361-8855
Page 7 of 9
POPULATE THE INSERT
Insert the Fiber Optic Termini into the back of the Insert Cavities. Place the Termini Retainer Plate between
the 900 µm fibers making sure that the springs are between the Fiber Optic Termini and Termini Retainer
Plate. Apply a drop of Loctite 222 to the Socket Head Cap Screw and use Hex Tool PT-504 to screw the
Termini Retainer Plate into the Insert. Torque the Socket Head Screw to the values in the above Torque
Table using Torque-Measuring Head Drive PT-590 and Bit Size 2.5 mm PT-599. Use a pair of Long Nose
Pliers PT- 532 to ensure the termini are fully seated against the ball lenses.
NOTE: See diagram below for polarity configurations:
Straight configuration is defined as A1 to A1, B1 to B1. Crossed configuration is defined as A1
to B1. Four channel layout uses the same pattern.