HARDWIRE TRANSLATOR & WIRELESS TRANSLATOR
GROUP
NAME
SUPERVISED
SCENARIO
13
Takeover
Y
Triggers an alarm when sensor is tampered in “Stay” or “Away”
mode
TILT
GROUP
NAME
SUPERVISED
SCENARIO
10
Entry-Exit- Normal Delay
Y
Triggers alarm after “normal delay” expires. Arms with both “Stay”
and “Away”
12
Entry-Exit- Long Delay
Y
Triggers alarm after “long delay” expires. Arms with both “Stay” and
“Away
25
Garage Tilt- Safety Tilt
Y
This sensor group does
not
report or trigger an alarm. This is a
chime only sensor when “Activity Monitoring” is active, regardless
of panel status. Great for detached garage/shops.
NOTE:
Functionality
in conjunction with garage door openers has not been evaluated for UL/cUL, UKCA or
CE/EN Grade 2.
*345 MHz tilt sensors can be programmed as “Loop” 3 only
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
70
197
SENSOR GROUPS