background image

IDENTIFICACIÓN DE PIEZAS DE RENOVACIÓN  CSDCSA, DSHCSA

For part numbers, refer to the Renewal
Parts Identification covering the appro-
priate height heater (7” or 14”), and
then select the front, back panel, or
grille listed under the 28” length.

IDENTIFICACIÓN DE PIEZAS DE RENOVACIÓN  CSHCRA, DSHCRA

DATOS DE ACCESORIOS

Descripción

Tapa de 

extremo-Izquierda

Tapa de 

extremo-Derecha

Sección  

de relleno

Esquina interior

Esquina exterior

Sección para

espacios libres

Sección de 

control, para

espacios libres

Cubierta de 

conducto 

1/8"

1/8"

0"   3"
3"   6"
6"   9"
9"   12"

15"  18"

3-12''

5-1/2''

1/2''

28''

3'
4'
5'
6'
8'

10'

28''

CSH05-ECL(R)

CSH05-ECR(R)

CSH05-FL3(R)
CSH05-FL6(R)
CSH05-FL9(R)

CSH05-FL12(R)
CSH05-FL18(R)

CSH05-IC1

CSH05-OC-1

CSH05-BL2-1
CSH05-BL3-1
CSH05-BL4-1
CSH05-BL5-1
CSH05-BL6-1
CSH05-BL8-1

CSH05-BL10-1

SHCC-05

CSH07-ECL(R)

CSH07-ECR(R)

CSH07-FL3(R)
CSH07-FL6(R)
CSH07-FL9(R)

CSH07-FL12(R)
CSH07-FL18(R)

CSH07-IC1

CSH07-OC-1

CSH07-BL2-1
CSH07-BL3-1
CSH07-BL4-1
CSH07-BL5-1
CSH07-BL6-1
CSH07-BL8-1

CSH07-BL10-1

CSH07-BCS-1

SHCC-07-14

CSH14-ECL(R)

CSH14-ECR(R)

CSH14-FL3(R)
CSH14-FL6(R)
CSH14-FL9(R)

CSH14-FL12(R)
CSH14-FL18(R)

CSH14-IC-1

CSH14-OC-1

CSH14-BL2-*
CSH14-BL3-*
CSH14-BL4-*
CSH14-BL5-*
CSH14-BL6-*
CSH14-BL8-*

CSH14-BL10-*

CSH14-BCS-*

SHCC-07-14

Adición de

longitud “N”

Número de catálogo

CSH05A            CSH07A            CSH14A

* Agregue el sufijo “1” para entrada inferior (por abajo), salida superior (por arriba).
Agregue el sufijo “3” para entrada inferior (por abajo), salida delantera (por delante).
† Diseñado para la instalación de componentes.
(R) Sufijo en número de catálogo se refiere a accesorios con tomacorriente de 120 VAC.

CSH05A, CSH07A y CSH14A

Descripción

Tapa de 

extremo-Izquierda

Tapa de 

extremo-Derecha

Sección  

de relleno

Esquina interior

Esquina exterior

Sección para

espacios libres

Sección de 

control, para

espacios libres

Cubierta de 

conducto 

1/8"

1/8"

0"   3"
3"   6"
6"   9"
9"   12"

15"  18"

3-12''

5-1/2''

1/2''

28''

3'
4'
5'
6'
8'

10'

28''

DSH05-ECL(R)

DSH05-ECR(R)

DSH05-FL3(R)
DSH05-FL6(R)
DSH05-FL9(R)
DSH05-FL12(R)
DSH05-FL18(R)

DSH05-IC1

DSH05-OC-1

DSH05-BL2-1
DSH05-BL3-1
DSH05-BL4-1
DSH05-BL5-1
DSH05-BL6-1
DSH05-BL8-1
DSH05-BL10-1

SHCC-05

DSH07-ECL(R)

DSH07-ECR(R)

DSH07-FL3(R)
DSH07-FL6(R)
DSH07-FL9(R)
DSH07-FL12(R)
DSH07-FL18(R)


CSH07-IC1
DSH07-OC-1

DSH07-BL2-1
DSH07-BL3-1
CSH07-BL4-1
CSH07-BL5-1
CSH07-BL6-1
DSH07-BL8-1
DSH07-BL10-1

DSH07-BCS-1

SHCC-07-14

DSH14-ECL(R)

DSH14-ECR(R)

DSH14-FL3(R)
DSH14-FL6(R)
DSH14-FL9(R)
DSH14-FL12(R)
DSH14-FL18(R)


DSH14-IC-1
DSH14-OC-1

DSH14-BL2-1*
DSH14-BL3-1*
DSH14-BL4-1*
DSH14-BL5-1*
DSH14-BL6-1*
DSH14-BL8-1*
DSH14-BL10-1*

DSH14-BCS-*

SHCC-07-14

Adición de

longitud “N”

Número de catálogo

CSH05A            CSH07A            CSH14A

* Agregue el sufijo “1” para entrada inferior (por abajo), salida superior (por arriba).
Agregue el sufijo “3” para entrada inferior (por abajo), salida delantera (por delante).
† Diseñado para la instalación de componentes.
(R) Sufijo en número de catálogo se refiere a accesorios con tomacorriente de 120 VAC.

CSH05A, CSH07A y CSH14A

REJILLA

PANEL TRASERO

TERMOSTATO SCR
(OPCIONAL

CONTROL 
PRINCIPAL
(OPCIONAL)

ESCLAVO
(OPCIONAL)

PANEL
DELANTERO

CUBIERTA
DELANTERA

TRANSFORMADOR DE
24V (OPCIONAL)

CONTROL NEUMÁTI-
CO (OPCIONAL)

RELÉ DE 
MERCURIO
(OPCIONAL)

INTERRUPTOR
AUTOMÁTICO
DE CIRCUITO
(OPCIONAL)

REJILLA

PANEL
TRASERO

INTERRUPTOR
DE DESCONEX-
IÓN (OPCIONAL)

TERMOSTATO
(OPCIONAL)

Descripción

Número de pieza

Esclavo

208/240 Voltios

Esclavo

277 Voltios

Control principal

208/240 Voltios

Control principal

277 Voltios

Termostato SCR

PANEL
DELANTERO

PANEL

TRASERO

REJILLA

Para números de piezas, consulte la
Identificación de Piezas de Renovación que
cubre el calefactor de altura apropiada 
(7” ó 14”), y luego seleccione el panel
delantero, trasero, o la rejilla enumerada bajo
la longitud de 28”.

PANEL
DELANTERO

PANEL
TRASERO

REJILLA

Para números de piezas, consulte la
Identificación de Piezas de Renovación 
que cubre el calefactor de altura apropiada
(7” ó 14”), y luego seleccione el panel
delantero, trasero, o la rejilla enumerada
bajo la longitud de 28”.

Controles opcionales

Descripción

Relé de mercurio, 1 polo, 

30 amperios, bobina de 24 voltios

Relé de mercurio, 1 polo, 

60 amperios, bobina de 24 voltios

Relé de mercurio, 1 polo, 

30 amperios, bobina de 120 voltios

Relé de mercurio, 1 polo, 

60 amperios, bobina de 120 voltios

Relé de mercurio, 1 polo, 

30 amperios, bobina de 208 voltios

Relé de mercurio, 1 polo, 

60 amperios, bobina de 208 voltios

Relé de mercurio, 1 polo, 

30 amperios, bobina de 240 voltios

Relé de mercurio, 1 polo, 

60 amperios, bobina de 240 voltios

Relé de mercurio, 1 polo, 

30 amperios, bobina de 227 voltios

Relé de mercurio, 1 polo, 

60 amperios, bobina de 227 voltios

Interruptor automático de circuito, 2 polos, 30 amps

Interruptor automático de circuito, 2 polos, 60 amps

Interruptor automático de circuito, 3 polos, 30 amps

Interruptor automático de circuito, 3 polos, 60 amps

Transformador de 24V, primario de 120 voltios

Transformador de 24V, primario de 208 voltios

Transformador de 24V, primario de 240 voltios

Transformador de 24V, primario de 227 voltios

Interruptor de desconexión

Termostato, 1 polo

Termostato, 2 etapas

Control neumático

Número de pieza

Descripción

Número de pieza

Controles opcionales

19

Summary of Contents for CSH05A

Page 1: ...ing this heater 7 This heater is not for residential or household use CSH and DSH Convectors Installation Operation Maintenance Instructions Commercial Sill Height Convection Heaters Type CSH GENERAL...

Page 2: ...ix with CSH05A 5 1 2 height heaters DSH05A 5 1 2 height heaters Model CSH05A DSH05A H 5 1 2 D 3 Table A Table A continued Amperage Catalog Length Total 208V 240V 277V Number L Watts Ft Watts 1 3 1 3 1...

Page 3: ...ishings Away From Heater For effi cient and safe operation we recommend maintaining a min imum of 6 inches 152 mm clearance above and in front of the heater at all times See Clearances Chart for minim...

Page 4: ...Minimum mounting heights above the floor shall be as follows Minimum Mounting Height Above Floor Watts Ft Heater Length Bottom Inlet Front Inlet 125 188 and 250 Watts Ft 1 3 4 0 376 500 625 and 750 3...

Page 5: ...with mounting screws See Figure 2 Installation of Multiple Wall to Wall Units Note For ease of installation it is important that the sequence of operations indicated below be followed in order 1 Remo...

Page 6: ...agram on control sections for connecting the wiring to the heaters Installation of Mullion to Mullion Units The back of the heater housing contains no mounting holes other than those at the ends and t...

Page 7: ...s since these could damage the finish or discolor in use 2 A vacuum cleaner and or compressed air may be used to remove dust and lint that may have accumulated inside heater around element fins If hea...

Page 8: ...8...

Page 9: ...07A CSH14A Add suffix 1 for bottom inlet top outlet Add suffix 3 for bottom inlet front outlet Intended for the installation of components R Suffix on catalog number refers to accessories with 120 VAC...

Page 10: ...Products THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXP...

Page 11: ...o en el interruptor de desconexi n principal o panel de servicio 7 Este calefactor no es para uso residencial ni hogare o Calefactores de convecci n CSH y DSH Instrucciones de instalaci n operaci n y...

Page 12: ...8125 125 1000 4 8 4 2 3 6 8188 8 188 1500 7 2 6 2 5 4 8250 250 2000 9 6 8 3 7 2 10125 125 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Prefijo con CSH05A calefactores c...

Page 13: ...io 4 Antes de instalar o energizar el calefactor remueva y deseche el material de empaque de espuma colocado dentro del calefactor 5 No instale el calefactor contra superficies combustibles de tabla d...

Page 14: ...portante seguir en orden la secuencia de operaciones indicada abajo 1 Remueva la cubierta delantera removiendo los tornillos de montaje Figura 2 2 Remueva la tapa precortada removible apropiada de cua...

Page 15: ...aciones indicada abajo 1 1 Remueva todas las cubiertas delanteras de los calefactores removiendo los tornillos de montaje Figura 2 2 Consulte el diagrama de cableado para la entrada del alambre s de a...

Page 16: ...bres a los calefactores Instalaci n de unidades de entreventana a entreventana miembro vertical intermedio en el marco de una ventana La parte trasera de la carcasa del calefactor no contiene orificio...

Page 17: ...da ar las aletas 3 Despu s de limpiar y suministrar servicio de mantenimiento siempre reensamble colocando nuevamente cualquier herraje removido y revise las unidades para verificar que est n funcion...

Page 18: ...Pie por elemento calefactor 250 W Pie por elemento calefactor Controles incorporados Opcional PANEL TRASERO PANEL TRASERO PANEL TRASERO REJILLA REJILLA REJILLA TERMOSTATO OPCIONAL TERMOSTATO OPCIONAL...

Page 19: ...1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Adici n de longitud N N mero de cat logo CSH05A CSH07A CSH14A Agregue el sufijo 1 para entrada inferior por abajo sa...

Page 20: ...ed Products LAS ANTERIORES GARANT AS REEMPLAZAN CUALQUIER OTRA GARANT A EXPRESA O IMPL CITA Y TODAS LAS GARANT AS IMPL CITAS DE MERCADE ABILIDAD Y ADECUADIBILIDAD PARA UN PROP SITO EN PARTICULAR QUE E...

Page 21: ...diateur est bien d branch en amont l interrupteur g n ral ou au pan neau de service avant d intervenir pour installer ou d panner ce radiateur 7 Ce radiateur n est pas pour une utilisation r sidentiel...

Page 22: ...25 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Pr fixe avec CSH05A radiateurs de 5 1 2 de haut CSH05A radiateurs de 5 1 2 de haut Mod les CSH05A DSH05A H 5 1 2 P 3 Tabl...

Page 23: ...die 4 Enlevez de l int rieur du radiateur et mettez au rebut les mat riaux d emballage en mousse avant d installer le radiateur et de le mettre sous tension 5 N installez pas le radiateur contre des s...

Page 24: ...t unique Remarque Pour faciliter l installation il est important que la s quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez le couvercle frontal en tant ses vis de fixation F...

Page 25: ...quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez tous les couvercles frontaux des radiateurs en tant leurs vis de fixation Figure 2 2 R f rez vous au sch ma de c blage pour...

Page 26: ...ils aux radiateurs Installation d unit de meneau meneau Le dos du carter de radiateur ne comporte pas de trous de montage autres que ceux dispos s aux extr mit s et de ce fait c est id al pour une ins...

Page 27: ...yant les ailettes d l ment pour ne pas les abimer 3 Apr s l intervention de nettoyage ou de service remettez bien en place au remontage toute la visserie enlev e et v rifiez le bon fonctionnement des...

Page 28: ...l ment 250 W pied par l ment Contr les int gr s Optionnel PANNEAU ARRI RE PANNEAU ARRI RE GRILLE GRILLE GRILLE PANNEAU ARRI RE THERMOSTAT OPTIONNEL THERMOSTAT OPTIONNEL PROTECTION CONTRE LES SURCHARGE...

Page 29: ...DSH14 FL3 R DSH14 FL6 R DSH14 FL9 R DSH14 FL12 R DSH14 FL18 R DSH14 IC 1 DSH14 OC 1 DSH14 BL2 1 DSH14 BL3 1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Extension...

Page 30: ...UTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D AD QUATION POUR UNE FINALIT SP CIFIQUE QUI EXC DERAIENT LES DISPOSITIONS DE GARANTIE PR C...