5 – NetWare Driver Installation
Driver Parameters
FL0054601-00 B
5-9
/COMPLEXTAG
Instance
This parameter enables SCSI complex tag queuing.
Complex tag queuing works as follows: the HACB
preserve order control flag enables ordered queuing, and
the HACB priority control flag enables head of queueing.
Otherwise, simple queuing is used.
/COMPLEXTAG parameter example:
LOAD QL2300.HAM SLOT=3 /LUNS /COMPLEXTAG
/XRETRY=
n
Instance
This parameter extends the retry count to
n
for any I/O
command that fails with the SCSI sense info
SK/ASC/ASCQ code in this list: 2/04/01, 6/8B/02.
/XRETRY=
n
parameter example:
LOAD QL2300.HAM SLOT=3 /LUNS /XRETRY=10
/XTIMEOUT=
n
Instance
This parameter extends the timeout value to
n
seconds
for any I/O command that times out (for example, the
command is held by the storage device for a long period
of time).
/XTIMEOUT=
n
parameter example:
LOAD QL2300.HAM SLOT=3 /LUNS /XTIMEOUT=120
/QUALIFIED
Instance
This parameter extends the inquiry data LUN present test
to allow RAID subsystem LUNs to be filtered as follows:
LUNs returning 20 XX (where XX is nonzero) are
reported; LUNs returning 20 00 are ignored.
/QUALIFIED parameter example:
LOAD QL2300.HAM SLOT=3 /LUNS /QUALIFIED
/LUNZERO
Instance
This parameter reports LUN 0 to NetWare, even if there
was no response to the SCSI Inquiry command (as long
as the port was logged in). This parameter is used for
RAID subsystems that do not report any LUNs on a port
until the subsystem is configured for the first time.
/LUNZERO parameter example:
LOAD QL2300.HAM SLOT=3 /ALLPATHS /LUNZERO
Table 5-1. QL2300.HAM Driver Parameters (Continued)
Parameter
Type
Description