background image

2

CPK-CAN

Dimensions

(Units : mm)

Wiring Instructions

Parts Definition/ Installation / Mounting Hole Specifications

• 

Machine holes on the mounting surface referring to

  the diagram below.

■ 

Mounting Hole Specifications

■ 

Parts Definition/ Installation

• First, machine taps or holes on the mounting surface

.

• The mounting hole of this product bracket is 4.5mm in diameter.

• When machining taps, fasten the bolt through the mounting hole of the bracket.

• When machining holes, insert the bolt through the hole of the bracket, and tighten the nut from the opposite side of the mounting surface.

80

15.4

80

59.6

75

63

62

62

CAN

(RS485)

I/O NC 8 7 6 5 4 3 2 1

GN

D

L(A)

H(B) RS

2

GN

D

RS

1

GN

D

T-REG

DC POWER

+ COM -

MAX.

Volume

4-M4 BOLT

Ø65.5

USB PORT

Front cover(ABS)

Bolt

Housing(ABS)

Packing

Nut

4-Ø4.5 HOLES

Ø66 HOLES

62

62

*1'

56

75(*

*1'

56

*1'

&$1+

&$1/

)XVH

'&32:(5
9a9

86%3257

Baud rate Select

RS2

RS1

Communication speed

OFF

OFF

125Kbps

OFF

ON

250Kbps

ON

OFF

500Kbps

ON

ON

1,000kbps

• How to set ‘T-REG’

  - If the product is installed at the end of CAN Networks, please add a terminating resistor to the ‘T-REG (Terminating Resistance)’ position of the 

    rear terminal blocks of the product.

  - The capacity of the terminating resistor is recommended with 120Ω/0.5W.

 - Please set RS1 and RS2 terminals on the backside of the unit for Baud rate setting.

• 

When wiring with power line, please check the voltage at the terminals.

- ON: RS1/RS2 terminals are connected to GND(  

 )

- OFF: RS1/RS2 terminals are NOT connected to GND (  

 )

 Applicable cable range : AWG16-AWG24

Reviews: