- 26 -
Tools
To help you for regular
maintenance, a set of tools is
provided in the tool box on the
rear left side of the vehicle.
Battery
Battery is normally stored
inside the guard board on the
right side of the frame. The
battery for the model may be of
conventional
type
or
maintenance-free type.
Direction for use of conventional
type battery:
MAX
MIN
Before using, fill electrolyte to
a level between the upper and
lower limits. During using, the
fluid level must be kept between
the upper limit and lower limit.
Warning
:
Once the battery has been in
use, no diluted sulfuric acid shall
be added. If the fluid level drops
below the lower limit, fill distilled
water to the upper limit. Never use
tap water.
Precaution
:
Never damage, clog or alter
the vent pipe for battery. Please
make sure that the vent hose is
connected to the vent fitting of
battery, with the other end kept
always open. The vent pipe and
battery shall be installed correctly.
The polarity of battery wiring
shall be always correct. Connect
the red wire to positive (+) and the
green wire to negative (-). Wrong
connection
may
damage
the
charging system and battery.
Note
:
After the first 1000 km and
every 3000 km, have the specific
gravity of each battery cell
checked by your distributor, by
using an electrolyte hydrometer.
1.
Safety
①
Electrolyte contains strong
acid and shall be prevented
from contacting the skin.
During operation, wear safety
helmet and safety clothing.
②
In case that electrolyte gets in
eyes, immediately wash the
eyes with plenty of clear
water for at least 15 minutes,
before going to hospital.
③
In case that electrolyte is
drunk, drink a large amount
of water or milk, and then