![QED Hammerhead Pro Field Service Manual Download Page 6](http://html1.mh-extra.com/html/qed/hammerhead-pro/hammerhead-pro_field-service-manual_765223006.webp)
O
Top Filling Pumps: Disassembly/Re-assembly for Cleaning
1.
Unscrew the bottom plug assembly
(counterclockwise) to remove it from
the pump casing.
2.
Remove remaining internal pump sub-
assembly – grasp top of pump, wiggle
side to side and twist while pulling out
of pump casing
3.
All parts are now removed from pump.
Clean as necessary. Reverse the process
to reassemble the pump, starting with
STEP 4
.
4.
Slide internal pump assembly into pump
casing. The o-ring should slide into the
casing.
NOTE:
the casing is universal – the pump
can slide into either end. (
See photo
).
5.
Screw the bottom inlet assembly back
into the pump casing and tighten
6.
Remove the barbed fitting from the
discharge check assembly. Remove the
check ball. Clean the check ball, check
seat & barbed fitting as necessary.
5