Pi HSC816 Installation Manual - Revision Beta
This document and product are copyrighted and all rights are reserved.
44
Program Codex remotes:
Two separate stages are required to program the Codex remote
Step 1
– Learn the remote into the HSC816
Step 2
– Define button functions.
Step 1 - Adding remotes
Enter programming mode
Select #6. Ready LED will flash slowly
Enter the remote number to be programmed on the keypad 1-8.Key 0 will toggle between Bank 1
and Bank 2 (9 to 16)
The remote number LED will flash.
Press the * key. The buzzer will beep and the instant LED will flash.
Press a button on the remote. The Instant LED will stop flashing and the remote number LED will be
on.
Step 2 - Assigning button functions
Press the “PROG” key. Remote number LED will switch off
Press the button to be allocated a function. (The existing function will be displayed).
Enter the desired function for this button from the table below. Corresponding function LEDs will light
Press “PROG” key to save
Repeat from step 2 for all remaining buttons.
Press the “BYPASS” key to exit programming for this remote.
Repeat from step 1 for all remaining remotes.
Button Function
Required Keystroke/s
Led Indication
Away arm with delay
Arm
Arm Led
Arm Instant
Arm + Instant
Arm + Instant Leds
Arm Home 1 with delay
Home (press once)
Home 1 Led
Arm Home 1 Instant
Home + Instant
Home 1 Led + Instant Leds
Arm Home 2 with delay
Home (press twice)
Home 2 Led
Arm Home 2 Instant
Home + Instant
Home 2 Led + Instant Leds
Panic audible
Panic
Zone 5 Led
Panic silent
Panic + Instant
Zone 5 + Instant Leds
Fire
Fire
Zone 6 Led
Medical
Medical
Zone 7 Led
Trigger 1
Key 1
Zone 1 Led
Trigger 2
Key 2
Zone 2 Led
Trigger 3
Key 3
Zone 3 Led
Trigger 4
Key 4
Zone 4 Led
To clear a function press the # key
Deleting Codex remotes:
Enter user programming mode Select # 6.Ready LED will flash slowly
Enter the remote number to be deleted.
The remote number LED will flash.
Press the # key, The buzzer will beep and the LED will switch off, indicating a blank location.
Programming keypad buzzer zones: (Keypad buzzer , no siren during an alarm condition)
Enter user programming.
Select # 7.
Select zone numbers to have Keypad buzzer facility
Key 0 will toggle between bank 1, (zones 1 to 8) and bank 2, (zones 9 to 16)
Zone numbers that are lit will be selected for keypad buzzer only
Press “PROG” key to save and exit.
Walk test
Enter user programming.
Select # 8.
Walk test all zones