QUESTION 54:
Auto test delay
Location 1
= Auto test delay
Location 2
=
Reserved
Location 3
= Reserved
Location 4
=
Reserved
Value
Delay
0
1 Day
1
2 Days
2
3 Days
3
4 Days
4
5 Days
5
6 Days
6
7 Days
7
8 Days
8
9 Days
9
10 Days
QUESTION 55:
Auto test time
L
ocation 1 = Hours x 10
Location 2 = Hours x 1
Location 3 = Minutes x 10
Location 4 = Minutes x 1
QUESTION 56:
Siren beep on exit time expired
Location 1
Value
Enable
0
1
QUESTION 57:
Keypad Options
Location 1 = Keypad panic
Location 2 = Error beep
Location 3 = Keypad tamper
Location 4 = # Key
Location 1
Location 2
Value
Panic audible
0
1
Location 3
Location 4
: # key (Hardwired trigger)
Entering 5 incorrect code sequences
or codex transmitter #0 to #9 (wireless trigger)
Value
Keypad tamper
0
1
QUESTION 58:
Siren Options
Location 1 = Alert on remote arm
Location 2 = Alert on keypad arm
Location 3 = Siren trip count per zone
Location 4 = Alert on home arm
Location 1
Location 2
Value
Remote arm
0
1
Location 3: Siren trip 0 to 9
Location 4
0 = No siren trip count.
Enter digit 1 to 9 for siren trip count per zone
Value
Error Beep enable
0
1
Value
Codex tx
0
1
Value
Keypad arm
0
1
Value
Home arm
0