![Q3 ENERGIE QFire Installation And Operation Manual Download Page 17](http://html1.mh-extra.com/html/q3-energie/qfire/qfire_installation-and-operation-manual_4364745017.webp)
Installation and Operation Manual
Q
F
ire – Fire Brigade Switch
3.2
PARTS LIST
Article number
Article description
Q
F
ire Control Box
500566
Q
F
ire Generator shut-down
control box
. With integrated evaluation of surge protection modules via LED. Con-
trol of Q
F
ire switch box in endless connection with slave boxes.
Q
F
ire Switch Box HV/HC
503122
Q
F
ire
Generator shut-down
switch box
HV/HC for switching of
2 strings
1000VDC/15ADC oder 1200VDC/
11A, extention by 2 strings
503101
Q
F
ire
Generator shut-down
switch box
HV/HC for switching of
4 strings
1000VDC/15ADC or 1200VDC/11A,
extention by 4 strings
503106
Q
F
ire
Generator shut-down
switch box
HV/HC for switching of
6 strings
1000VDC/15ADC or 1200VDC/11A.
Module connectors MC4. Housing polycarbonate 300 x 400. Membrane for pressure balance.
503108
Q
F
ire
Generator shut-down
switch box
HV/HC for switching of
8 strings
1000VDC/15ADC or 1200VDC/11A.
Module connectors MC4. Housing polycarbonate 300 x 400 mm. Membrane for pressure balance.
510610
Q
F
ire Generator shut-down
switch box
HV
for switching of
10
strings
(1:1 with or without slave may be listed
as a separate position) Remote-controlled switching unit "Q
F
ire" for separating 10 PV strings (10 x plus & 10 x
minus). Output (10 outputs - 10 x plus & 10 x minus) IP64 polycarbonate enclosure for outdoor installation in
weatherproof environments, 600 x 400 mm. String connection input and output via MC4 plug. Connection of
the control cable in the box. Maximum string voltage 1500VDC at max. 11 A or 1200 VDC at up to 15A per
string. 6 pieces of mounting ears pre-assembled. Connection of the 4-pin control cable (on-site) via spring-loa-
ded terminals, cable grommet M25
510612
Q
F
ire Generator shut-down
switch box
HV
for switching of
12
strings
(1:1 with or without slave may be listed
as a separate position) Remote-controlled switching unit "Q
F
ire" for separating 10 PV strings (10 x plus & 10 x
minus). Output (10 outputs - 10 x plus & 10 x minus) IP64 polycarbonate enclosure for outdoor installation in
weatherproof environments, 600 x 400 mm. String connection input and output via MC4 plug. Connection of
the control cable in the box. Maximum string voltage 1500VDC at max. 11 A or 1200 VDC at up to 15A per
string. 6 pieces of mounting ears pre-assembled. Connection of the 4-pin control cable (on-site) via spring-loa-
ded terminals, cable grommet M25
510614
Q
F
ire Generator shut-down
switch box
HV
for switching of
12
strings
(1:1 with or without slave may be listed
as a separate position) Remote-controlled switching unit "Q
F
ire" for separating 10 PV strings (10 x plus & 10 x
minus). Output (10 outputs - 10 x plus & 10 x minus) IP64 polycarbonate enclosure for outdoor installation in
weatherproof environments, 600 x 400 mm. String connection input and output via MC4 plug. Connection of
the control cable in the box. Maximum string voltage 1500VDC at max. 11 A or 1200 VDC at up to 15A per
string. 6 pieces of mounting ears pre-assembled. Connection of the 4-pin control cable (on-site) via spring-loa-
ded terminals, cable grommet M25
510616
Q
F
ire Generator shut-down
switch box
HV
for switching of
16
strings
(1:1 with or without slave may be listed
as a separate position) Remote-controlled switching unit "Q
F
ire" for separating 10 PV strings (10 x plus & 10 x
minus). Output (10 outputs - 10 x plus & 10 x minus) IP64 polycarbonate enclosure for outdoor installation in
weatherproof environments, 600 x 400 mm. String connection input and output via MC4 plug. Connection of
the control cable in the box. Maximum string voltage 1500VDC at max. 11 A or 1200 VDC at up to 15A per
string. 6 pieces of mounting ears pre-assembled. Connection of the 4-pin control cable (on-site) via spring-loa-
ded terminals, cable grommet M25
Accessories
500001
Q
F
ire Power Off - red central EMERGENCY OFF, potential-free switch in series. Connection for 2.5 mm
2
X502102
Assembly for renewal of the control signal, slave integrated into the switch box.
991010
Delay circuit for Q
F
ire. Shutdown delay 1 second per switch box in series. Assembled and pre-tested PCB with
connection tabs.
595012
Surge protection T1/2 combi operator with telecommunication contact for integration into a Q
F
ire switch box.
500003
Key switch
Q3 Energie GmbH & Co. KG
Phone
+49 (0)8341/9080 334
IA-BA_QFire _E_AS002_V1.0
Moosmangstr. 8
Status
March 15, 2024
Page
17 | 28
87600 Kaufbeuren
Our general terms of business are to be applied.
Germany
Web
www.q3-energie.de
Errors and changes reserved.
eh
alten.