INSTALLATION
Q6S/Q6M
© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com
Specification subject to change. Rev-09-29-20
Connecting and Configuring
B
E
A
C
B
D
PRIMARY (Input Wires)
SECONDARY (Output Wires)
CHOKE
Standard on all units
TRANSFORMER
Small – 50W - 300W
DIVIDER
A
B
C
D
E
Input voltage is fixed and can only be changed
at the factory. Input voltage is indicated on side
of the housing.
Medium – 500W - 750W
Large – 900W - 1800W
Secondary Circuit Breakers
Secondary Common
DO NOT EXCEED TOTAL AMPS OF SECONDARY
CIRCUIT BREAKERS
Output voltage is wired as ordered (12V or 24V)
but can be changed by a licensed electrician.
CHOKE
GREEN
GND
NEU
HOT
GND
NEU
HOT
GND
WHITE
TAP1
(120V)
BLACK
ORANGE
(277V)
WHITE
BROWN
BLUE
YELLOW
VIOLET
Tp
Bkr(s).
PRIMARY
VOLTAGE
12V
WIRING DIAGRAM
24V
WIRING DIAGRAM
SECONDARY
12 VAC
Ɣ
USE WIRE NUTS OR TERMINAL BLOCKS FOR LOAD CONNECTIONS
Ɣ
DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING
L
O
A
D
L
O
A
D
OR
TAP2
(120V)
GREY
RED
(277V)
CHOKE
GREEN
GND
WHITE
TAP1
(120V)
BLACK
ORANGE
(277V)
WHITE
BROWN
BLUE
YELLOW
VIOLET
Tp
Bkr(s).
PRIMARY
VOLTAGE
SECONDARY
24 VAC
Ɣ
USE WIRE NUTS OR TERMINAL BLOCKS FOR LOAD CONNECTIONS
Ɣ
DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING
L
O
A
D
L
O
A
D
OR
TAP2
(120V)
GREY
RED
(277V)
4.50"
Q6 WIRING DIAGRAM
3.50"
If a transformer is wired from the factory for 12V,
for 24V secondary wiring: Disconnect the blue and
yellow wires from terminal blocks and connect
together with wire nut. The brown wire now
becomes the common side of the load, and the
violet wire should be connected to the secondary
circuit breaker, which is the line side of the load.
Please refer to the wiring diagrams on this page.
12
24
If a transformer is wired from the factory for
24V, for 12V secondary wiring: Disconnect the
blue and yellow wires from terminal block.
Connect yellow and brown wire into terminal
block, which becomes the common side of the
load. Connect blue and violet wires into
terminal block, which should be connected to
the secondary circuit breaker(s) which
becomes the line side of the load Please refer
to the wiring diagrams on this page.
24
12
Auto reset thermal circuit breaker mounted to core of toroid Hydraulic magnetic manual reset circuit breakers
Tp
Terminal block connection
Polarity
Choke or inductor on primary
to reduce inrush current.