10
Clean-up:
Always clean the gun at the end of the day
or between colors
1.
U s i n g a r a g m o i s t e n e d w i t h a
compatible solvent, clean the cup and
the outside of the gun.
2.
Remove the Air Cap, Baffle and Nozzle
and clean with a cleaning brush. Take
care to avoid damage to the air cap
holes.
3.
Remove the needle and clean. Clean
the paint carrying orfices of the gun.
Do not allow solvent to enter the air
carrying orfices of the gun. Therefore
point the gun down while cleaning the
paint orfices.
Never soak the entire gun in solvent.
Using Optional Remote Pressure Pots:
The standard set-up of this gun is as an HVLP
turbine cup-feed gun. It is also possible
to use this gun and turbine with a remote
pressure pot (pressure feed set-up). All
that is necessary is to convert the gun. To
convert:
1.
Use an appropriate wrench to loosen
the nut to remove the paint cup.
2.
Connect the hose from the pressure
pot.
3.
Use an appropriate wrench to unscrew
the nipple for the vent tube from the
gun body.
4.
Use a bolt with the correct thread to
plug the hole from the nipple.
Pressure relief procedure:
When using a pressure pot, the pot must
always be relieved of pressure before
opening. To relieve pressure:
1.
Shut off the air supply to the pot.
2.
Open the pressure relief valve on the
pot.
Maintenance:
1.
Keep the gun clean
2.
Keep the inlet filters of the turbine
clean.
Entrust repairs to a qualified service
technician
WRONG