29
Pick-Point Deployment
Single Pick-Point Deployment
For single pick-point deployments, a 16 mm (5/8 in.) shackle (not included) can be attached to the
center rail of the Array Frame at the center-of-gravity (CG) point for the desired angle.
Dual Pick-Point Deployment
For a dual pick-point deployment with two pick-points, two 16 mm (5/8 in.) shackles (not included)
can be attached to the center rail of the Array Frame at the CG point for the desired angle.
NOTE:
Use EASE Focus 3 (available online) to locate the CG point and desired
vertical angle for specific deployments.
Bridle Deployment
For a bridle deployment with two pick-points, two 16 mm (5/8 in.) shackles (not included) can be
attached to the two outer rails of the Array Frame at the CG point for the desired angle.
NOTE:
Use EASE Focus 3 (available online) to locate the CG point and desired
vertical angle for specific deployments.
Adjusting the Tilt Angle of the Array on a Pick-Point Deployment
The tilt angle of the array can be adjusted for single pick-point and bridle deployments by moving the shackle(s) forward or backward
on the Array Frame. A greater uptilt can be achieved by reversing the loudspeaker on the array frame or using the extension bar.
Pick-Point 11
Pick-Point 11
Pick-Point 11
Pick-Point 1
Pick-Point 1
Pick-Point 1
Figure 30
WARNING!:
Rigid mounting of the frame may affect the Factor of Safety because it forces the array into position. It is
preferred to use a Pullback Bar.
Figure 27
Figure 28
Figure 29