INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNWHa Q CeLLS aUSTraLIa PTY LTD
INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNWHa Q CeLLS aUSTraLIa PTY LTD
19
18
Ä
use solar cables for the connection at
the junction box outlet.
Ä
use the same, inverter-compatible plugs.
SOLAR
NOTE
! Module damage may occur!
Ä
ensure that the cabling is not under
stress.
Ä
ensure that the cables do not run
between module and subconstruction
(danger of pinch).
Ä
Do not connect modules with different
orientations or angles of inclination in
the same string.
Ä
ensure for a tight connection between
the plugs. Plugs click together audibly.
click
DANGER
! Risk of fatal injury due to electric
shock!
Ä
ensure that all electrical components are
in a proper, dry, and safe condition.
•
A module with 1,160 mm long cable can
be wired as a "2nd next neighbor".
"2nd next neighbor" - Wiring without a
return cable.
standard wiring with a return cable.
Inverter
Inverter
1
2
4.3 Connection of modules
4
eLeCTrICaL CoNNeCTIoN
Ä
ensure that all necessary safety and
functional tests have been carried out
according to current industry standards.
NOTE
! Module damage may occur!
Ä
ensure that the plug connections are not
level with a water-channeling surface.
Ä
integrate the system into the existing
lightening protection system in
accordance with the applicable local
regulations.
WARNING
! Fire Risk!
Ä
Do not use light concentrators (e.g.
mirrors or lenses).
Ä
ensure that cables are protected from
abrasion, tension, compression and
cutting forces in full accordance with
As / NZs 3000.
4.4 after installation
4
eLeCTrICaL CoNNeCTIoN