INSTALLATION AND OPERATION MANUAL SOLAR MODULES – Q.PRO L-G4.1, Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2 – NA

INSTALLATION AND OPERATION MANUAL SOLAR MODULES – Q.PRO L-G4.1, Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2 – NA

2 PLANNING

2.3  Mounting options

Specifications 

MODULE TYPE

MOUNTING OPTION

CLAMPING AREA

1

 [IN (MM)]

TEST-LOAD ACCORDING  
IEC 61215  
PUSH/PULL [PA] 

Q.PRO L-G4.1 

Q.PRO L-G4.2

Q.PLUS L-G4.1 

Q.PLUS L-G4.2

CL1 (4 point clamping on long 

side)

9.8-19.7 (250-500)

5400/2400

CL3 (4 point clamping on long 

side)

9.8-19.7 (250-500)

3600/2400

FB1 (4 screws mounting on long 

module side)

13.5 (343)

5400/2400

IP1 (Slide-in / long  

module side)

3600/2400

1

 

Distance between outer edge of module and middle of the clamp.

DISTANCE BETWEEN MODULES

 

Ä

 Maintain an interval of at least 0.39 in (10 mm) between two modules along the short side

 

Ä

 Maintain an interval of at least 0.20 in (5 mm) between two modules along the long side

MOUNTING OPTIONS CL1

 

Ä

Ensure, that the subconstruction does not run below the junction box.

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

MOUNTING OPTION FB1

 

Ä

Use M8 corrosion-proof screws and washers (min. diameter 0.63 in (16 mm)).

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

• 

The fastening points are located on the backside of the module frame.

Module Selection

For detailed key electrical data, please refer to the product data 
sheet for the respective product. 

 

Ä

Only connect modules of the same type and the same power 
class.

Safety Factor

During normal operation, a module may generate a greater current 
and / or higher voltage than that determined under standardized test 
conditions. Please use a safety factor of 1.25 for the following:

• 

Calculating the voltage measurement values (V

oc

) of components 

• 

Calculating the current measurement values (I

SC

) of conductors

• 

Sizing of control systems connected to the outlets of the solar 
modules 

 

Ä

Please follow the valid national guidelines for the installation 
of electrical systems (refer to section 690-8 of the NEC for an 
additional multiplying factor of 125 percent [80 percent derating] 
which may be applicable).

Series Connection

Connection of modules in series is only permitted up to the 
maximum system voltage as listed in the applicable data sheet.  

 

Ä

Take into account all possible operating situations and all relevant 
technical norms and regulations when designing the system. 
This will ensure that the maximum system voltage, including all 
necessary safety margins, is not exceeded. 

 

Ä

Take the voltage limit of the inverter into account when determining 
the maximum number of modules in the string.

Parallel Connection

Modules may be damaged by the occurrence of reverse currents 
(caused by module defects, ground leaks, or defective insulation).

 

Ä

Ensure that the maximum reverse current load capacity indicated 
in the data sheet is met. 

In order to limit reverse currents that may occur, we recommend 
using the following safety options:

1)  Layout with a limited number of parallel connected strings :

Without undertaking further current blocking measures, a maximum 
of two module strings may be operated in parallel on an inverter or 
MPP tracker.

2)  Layout with string fuses :

Place fuses for each string of modules at the plus and minus ends. 
Observe the maximum permitted number of strings as indicated 

in the specifications provided by the respective string fuse manu

-

facturer and the technical guidelines.

NOTE! 

When installing different product versions, the lowest minimum 
permitted reverse current load capacity applies.  

Inverters

Inverters with or without transformers may be used.

2.4  Electrical layout

2 PLANNING

Summary of Contents for Q.PLUS L-G4.1

Page 1: ...Valid for North America Q PRO L G4 1 Q PLUS L G4 1 Q PRO L G4 2 Q PLUS L G4 2 INSTALLATION AND OPERATION MANUAL ...

Page 2: ...amage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Units Where both metric and U S units for example inches are shown metric units are definitive References to Data Sheet or Module Data Sheet refer to the Module Data Sheet applicable to the module being used Safety Regulations The solar module operator is responsible f...

Page 3: ...documents This installation manual is only valid in combination with the following technical information DOCUMENT TYPE Product data sheet Packaging and transport information 1 INTRODUCTION 2 1 Technical specifications 2 PLANNING Fig 1 External dimensions inch and mm and components for Q PRO L G4 1 Q PRO L G4 2 Q PLUS L G4 1 Q PLUS L G4 2 C SI MODULES L FOR DATA SHEETS 47 24 1200 mm 39 4 1000 mm 51...

Page 4: ...s to prevent contact corrosions Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ä Ä Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Use customary clamps that comply with the requirements Clamp width 1 50in 38 mm Cl...

Page 5: ...25 for the following Calculating the voltage measurement values Voc of components Calculating the current measurement values ISC of conductors Sizing of control systems connected to the outlets of the solar modules Ä Ä Please follow the valid national guidelines for the installation of electrical systems refer to section 690 8 of the NEC for an additional multiplying factor of 125 percent 80 perce...

Page 6: ...e modules securely in cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your vendor of any damages immediately 3 1 Safety and transport 3 INSTALLATION NOTE Module damage may occur Ä Ä Do not drop modules NOTE Module damage may occur Ä Ä Only make modifications to the module which have been confirmed ...

Page 7: ...o electric shock Ä Ä Only use dry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not drill any other holes e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION Ä Ä Maintain an interval of at least 0 39 in 10 mm between two modules along the short side and 0 20 in 5 mm along the long side 0 39 in 10mm ...

Page 8: ...ted at the inverter prior to separation Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Change of bypass diodes is only allowed by qualified and trained personnel in disconnected and covered state DANGER Risk of fatal injury due t...

Page 9: ... shock Ä Ä Ensure that all electrical components are in a proper dry and safe condition A module with min 47 24in 1 200 mm long cable in portrait orientation can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cable Standard wiring with a return cable Inverter Inverter 1 2 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functiona...

Page 10: ... 0 0 8 0 0 08 0 79 0 47 0 08 PV Laminate Backing Nut Stainless Steel Toothed Lock Washer Stainless Steel or tin plated metal Grounding Lug Stainless Steel Equipment Grounding Conductor Aluminum Frame Screw Stainless Steel with a ground symbol as shown below on the frame section drawing To install the grounding lug follow the specified instructions of the manufacturer The grounding lug should be ma...

Page 11: ...cured access Ä Ä Never access the installation area alone or without taking adequate security precautions Ä Ä Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Ä Ä Remove snow and ice without force e g with a very soft broom Ä Ä Do not scratch off dirt Ä Ä Rinse dirt off with lukewarm water dust leaves etc Ä Ä Use a soft cellulose cloth kitchen ...

Page 12: ...0 Spectrum Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 EMAIL q cells usa q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS Installation manual Q PRO L G4 X Q PLUS L G4 X_2016 02_Rev03_NA ...

Reviews: