DANGER!  
Risk of fatal injury due to electric shock!

When disconnecting an electric circuit carrying direct current, 
electric arcs can occur that may result in life-threatening injuries.

 

Ä

Do NOT unplug the cable when under load.

 

Ä

Do NOT connect any exposed cable ends.

 

Ä

Do NOT touch the poles at the same time.

A solar module generates electrical current and voltage even at a 
low intensity of illumination. Sparks and electric arcs may result 
from the separation of a closed circuit. These can result in life-
threatening injuries. The danger increases when several modules 
are connected in series.

 

Ä

Please be aware of the entire open circuit voltage is active even 
at low levels of solar irradiation. 

 

Ä

Please follow the valid national regulations and safety guidelines 
for the installation of electrical devices and systems.

 

Ä

Please make sure to take all necessary safety precautions. With 
module or phase voltages of more than 120 V, the extra-low 
voltage range is exceeded.

 

Ä

Carry out work on the inverter and the wiring with extreme caution.

 

Ä

Ensure that the modules are disconnected at the inverter prior 
to separation.

 

Ä

Be sure to observe the specified time intervals after switching off 

the inverter. High-voltage components need time to discharge.

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Never open the junction box.

 

Ä

Change of bypass diodes is only allowed by 

qualified and trained personnel in disconnected 

and covered state.

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Never touch live contacts with bare hands.

 

Ä

Do not touch the poles at the same time.

 

Ä

Cover connectors by suitable protective caps until 
installation.

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Insulate any exposed cable ends.

 

Ä

Only connect cables with plugs.

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Only use dry, insulated tools for electrical work.

4.1  Safety

ELECTRICAL CONNECTION

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Ensure correct polarity.

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Be sure to maintain the time intervals as specified 

by the inverter manufacturer between switching off 
the inverter and beginning any further work.

DANGER

! Risk of fatal injury due to electric shock! 

 

Ä

Never unplug the cable when under load.

1.

 Switch off the inverter.

OFF

EN

3.

 Switch off the DC circuit breaker.

 

Ä

Disconnect plugs by the use of appropriate 

and qualified tools of the manufacturer Tyco or 

Multicontact (adequate for PV4 plug type).

2.

 Cover the modules to be disconnected.

4.2  Electrical installation safety

ELECTRICAL CONNECTION

Summary of Contents for Q.PLUS L-G4.1

Page 1: ...Valid for North America Q PRO L G4 1 Q PLUS L G4 1 Q PRO L G4 2 Q PLUS L G4 2 INSTALLATION AND OPERATION MANUAL ...

Page 2: ...amage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Units Where both metric and U S units for example inches are shown metric units are definitive References to Data Sheet or Module Data Sheet refer to the Module Data Sheet applicable to the module being used Safety Regulations The solar module operator is responsible f...

Page 3: ...documents This installation manual is only valid in combination with the following technical information DOCUMENT TYPE Product data sheet Packaging and transport information 1 INTRODUCTION 2 1 Technical specifications 2 PLANNING Fig 1 External dimensions inch and mm and components for Q PRO L G4 1 Q PRO L G4 2 Q PLUS L G4 1 Q PLUS L G4 2 C SI MODULES L FOR DATA SHEETS 47 24 1200 mm 39 4 1000 mm 51...

Page 4: ...s to prevent contact corrosions Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ä Ä Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Use customary clamps that comply with the requirements Clamp width 1 50in 38 mm Cl...

Page 5: ...25 for the following Calculating the voltage measurement values Voc of components Calculating the current measurement values ISC of conductors Sizing of control systems connected to the outlets of the solar modules Ä Ä Please follow the valid national guidelines for the installation of electrical systems refer to section 690 8 of the NEC for an additional multiplying factor of 125 percent 80 perce...

Page 6: ...e modules securely in cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your vendor of any damages immediately 3 1 Safety and transport 3 INSTALLATION NOTE Module damage may occur Ä Ä Do not drop modules NOTE Module damage may occur Ä Ä Only make modifications to the module which have been confirmed ...

Page 7: ...o electric shock Ä Ä Only use dry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not drill any other holes e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION Ä Ä Maintain an interval of at least 0 39 in 10 mm between two modules along the short side and 0 20 in 5 mm along the long side 0 39 in 10mm ...

Page 8: ...ted at the inverter prior to separation Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Change of bypass diodes is only allowed by qualified and trained personnel in disconnected and covered state DANGER Risk of fatal injury due t...

Page 9: ... shock Ä Ä Ensure that all electrical components are in a proper dry and safe condition A module with min 47 24in 1 200 mm long cable in portrait orientation can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cable Standard wiring with a return cable Inverter Inverter 1 2 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functiona...

Page 10: ... 0 0 8 0 0 08 0 79 0 47 0 08 PV Laminate Backing Nut Stainless Steel Toothed Lock Washer Stainless Steel or tin plated metal Grounding Lug Stainless Steel Equipment Grounding Conductor Aluminum Frame Screw Stainless Steel with a ground symbol as shown below on the frame section drawing To install the grounding lug follow the specified instructions of the manufacturer The grounding lug should be ma...

Page 11: ...cured access Ä Ä Never access the installation area alone or without taking adequate security precautions Ä Ä Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Ä Ä Remove snow and ice without force e g with a very soft broom Ä Ä Do not scratch off dirt Ä Ä Rinse dirt off with lukewarm water dust leaves etc Ä Ä Use a soft cellulose cloth kitchen ...

Page 12: ...0 Spectrum Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 EMAIL q cells usa q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS Installation manual Q PRO L G4 X Q PLUS L G4 X_2016 02_Rev03_NA ...

Reviews: