INSTALLATION AND OPERATION MANUAL SOLAR MODULES DUO-G5.X – Q CELLS

INSTALLATION AND OPERATION MANUAL SOLAR MODULES DUO-G5.X – Q CELLS

Validity

These instructions are only valid for crystalline solar modules from 
the company Q CELLS as specified at chapter „2.1 Technical 
Specifications“. Q CELLS assumes no liability for damage resulting 
from failure to observe these instructions. 

 

Ä

Please observe the wiring and dimensioning of the system.

 

Ä

The installer of the system is responsible for compliance with all 
necessary safety regulations during set-up and installation.

Q CELLS assumes no liability on the basis of these instructions. 
Q CELLS is only liable in the context of contractual agreements 
or in the context of accepted guarantees. Q CELLS accepts no 
other responsibility for the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other system compo-
nents that may be part of the complete solar power system. 
It may be necessary to carry out a structural analysis for the 
entire project. 

 

Ä

If your questions are not satisfactorily answered in the manual, 
please contact your system supplier.

Additional information can be found on our website at 
www.q-cells.com.

Information for the Operator

 

Ä

Please keep this installation manual for the entire life of the 
solar power system.

 

Ä

Please contact your system supplier for information concerning 
the formal requirements for solar power systems.

 

Ä

Please be sure to contact the relevant local authorities and 
energy providers regarding regulations and permit requirements 
prior to installation of the solar power system. Your financial 
success depends on the fulfillment of these requirements.

Other applicable documents

This installation manual is only valid in combination with the following 
technical information.

DOCUMENT TYPE

Product data sheet

Packaging and transport information

MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE 
LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD 
AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER 
INSTALLATION OR CONFIGURATION, IM PROPER MAINTENANCE, 
UNINTENDED USE, AND UNAUTHORIZED MODIFICATION.

Fig. 1: 

External dimensions (in inch (mm)) and components for  
Q.PEAK DUO-G5, Q.PEAK DUO BLK-G5, 
Q.PLUS DUO-G5, Q.PLUS DUO BFR-G5, 
Q.PEAK DUO-G5.2, Q.PEAK DUO BLK-G5.2, 
Q.PLUS DUO-G5.2, Q.PLUS DUO BFR-G5.2

NA

DETAIL A 0.630" (16 mm)

0.335" (8.5 mm)

0.965" (24.5 mm)

38.58" (980 mm)

66.3" (1685 mm) 

4 × Mounting slots (DETAIL A)

Frame

39.4" (1000 mm)

37.44" (951 mm)

1.26" (32 mm)

8 × Drainage holes

13.9“ (352.5 mm)

4 × Grounding points ø 0.177" (4.5 mm)

 43.3“ (

 110

0 mm)

 43.3“ (

 110

0 mm)

Label

For additional information see the relevant datasheet of the module provided at www.q-cells.com.

PRODUCT LINE

Q.PEAK DUO-G5
Q.PEAK DUO BLK-G5
Q.PLUS DUO-G5
Q.PLUS DUO BFR-G5

Q.PEAK DUO-G5.1
Q.PLUS DUO-G5.1

Q.PEAK DUO-G5.2
Q.PEAK DUO BLK-G5.2
Q.PLUS DUO-G5.2 
Q.PLUS DUO BFR-G5.2

Q.PEAK DUO-G5.3
Q.PLUS DUO-G5.3

Type

Q.ANTUM DUO

Q.ANTUM DUO

Q.ANTUM DUO

Q.ANTUM DUO

Length [in]

66.3  (1685 mm)

66.3  (1685 mm)

66.3  (1685 mm)

66.3  (1685 mm)

Width [in]

39.4  (1000 mm)

39.4  (1000 mm)

39.4  (1000 mm)

39.4  (1000 mm)

Frame height [in]

1.26  (32 mm)

1.26  (32 mm)

1.26  (32 mm)

1.26  (32 mm)

Area [yd²]

2  (1.69 m²)

2  (1.69 m²)

2  (1.69 m²)

2  (1.69 m²)

Weight [lbs]

41.2  (18.7 kg)

42.3  (19.2 kg)

41.2  (18.7 kg)

42.3  (19.2 kg)

Max. system voltage V

SYS

1000 V

1000 V

1500 V

1500 V

Max. series fuse rating

20 A

20 A

20 A

20 A

Permissible  

temperature range

–40 °F bis +185 °F (–40 °C to +85 °C)

Junction box  

protection class

IP67 with bypass diode

Connector protection 

class

IP68

Fire protection class

C / TYPE  2

C / TYPE  2

C / TYPE  1

C / TYPE  1

Max. test load  

Push/Pull

1

 [lbs/ft²]

113 / 84
(5,400 Pa / 4,000 Pa)

113 / 84
(5,400 Pa / 4,000 Pa)

113 / 84
(5,400 Pa / 4,000 Pa)

113 / 84
(5,400 Pa / 4,000 Pa)

Max. design load  

Push/Pull

1

 [lbs/ft²]

75 / 55
(3,600 Pa / 2,667 Pa)

75 / 55
(3,600 Pa / 2,667 Pa)

75 / 55
(3,600 Pa / 2,667 Pa)

75 / 55
(3,600 Pa / 2,667 Pa)

Certificates

VDE Quality Tested; CE-compliant; IEC 61215:2016; IEC 61730:2016; Application Class II; UL 1703

1

  Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3 Mounting Options“)

1  INTRODUCTION

2  PLANNING

2.1  TECHNICAL SPECIFICATIONS

Fig. 2: 

External dimensions (in inch (mm)) and components for  
Q.PEAK DUO-G5.1, Q.PLUS DUO-G5.1,  
Q.PEAK DUO-G5.3 and Q.PLUS DUO-G5.3

NA

DETAIL A 0.630" (16 mm)

0.335" (8.5 mm)

0.965" (24.5 mm)

38.58" (980 mm)

66.3" (1685 mm) 

Frame

39.4" (1000 mm)

37.44" (951 mm)

1.26" (32 mm)

8 × Drainage holes

13.9“ (352.5 mm)

4 × Grounding points 
ø 

0.177" (

4.5 mm)

Label

4 × Mounting slots 
(DETAIL A)

 47

.2“ (

≥ 1200 

mm)

 47.2“ (

≥ 1200 

mm)

Summary of Contents for Q.PEAK DUO-G5 series

Page 1: ...Valid for North America INSTALLATION AND OPERATION MANUAL DUO G5 X solar module series...

Page 2: ...llowing regulations and standards must be upheld at all times during the installation operation and maintenance of the solar modules Installation and Operation Manual Other applicable documents such a...

Page 3: ...ORIZED MODIFICATION Fig 1 External dimensions in inch mm and components for Q PEAK DUO G5 Q PEAK DUO BLK G5 Q PLUS DUO G5 Q PLUS DUO BFR G5 Q PEAK DUO G5 2 Q PEAK DUO BLK G5 2 Q PLUS DUO G5 2 Q PLUS D...

Page 4: ...ns Operating temperatures from 40 F to 185 F Pull loads and push loads according to chapter 2 3 Test Load in accordance with IEC 61215 and Design Load 1 5 in accor dance with UL 1703 Installation usin...

Page 5: ...3 88 352 5 IP1 CL1 0 9 84 0 250 17 72 21 65 450 550 2400 2400 1600 1600 CL2a with rails CL2b without rails 0 11 81 0 300 CL4 0 11 81 0 300 CL5 short side 0 9 84 0 250 long side 11 81 17 72 300 450 400...

Page 6: ...g the maximum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ensure that...

Page 7: ...e damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 INSTALLATION 3 1 SAFETY AND TRANSPORT DANGER Risk of fatal inju...

Page 8: ...result from the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open c...

Page 9: ...ersonnel see page 3 Ensure correct polarity Use solar cables for the connection at the junction box outlet Use the same inverter compatible plugs Use minimum No 12 AWG copper wires insulated for a min...

Page 10: ...l shock or fire the frame of the module as well as any non current carrying metal parts of the system must be grounded While this section provides some information about grounding the Q CELLS frames a...

Page 11: ...rost 0 6 MAINTENANCE AND CLEANING Free the substructure from any dirt and debris leaves bird nests etc Remove dirt with lukewarm water or alcohol based glass cleaner a broom or a soft cloth Do not use...

Page 12: ...400 Spectrum Center Drive Suite 1400 Irvine CA 92618 USA TEL 1 949 748 59 69 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Q CELLS Installation manual solar modules...