14
ENFORCER V11 INSTALLATION GUIDE
Wireless ZEM header addressing
WIRELESS ZEM
ADDRESS
DEVICE A
(0-3)
DEVICE B
(4-7)
DEVICE C
(8-11)
ZEM32-WE
ZEM address 00
OFF
ON
OFF
ZEM address 01
OFF
ON
OFF
ZEM address 02
OFF
ON
OFF
ZEM address 03
OFF
ON
OFF
Wireless ZEM zone mapping
WIRELESS ZEM
ADDRESS
ZONES
ZEM32-WE
ZEM address 00
35-42
ZEM address 01
43-50
ZEM address 02
51-58
ZEM address 03
59-66
Please note: Wireless zones 35-66 can take upto 5 minutes to become active when armed.
Connecting an output expander
1 remote output expander can be connected to the Enforcer. The output expander allows 16 additional outputs.
PGM STB BELL
Z33 COM +12V Z34
D1- D2+ D3
D4
D1- D2+ D3 D4
D1- D2+ D3 D4
Please note: The above shows the I/O board connected to a EURO-OEM8R8T. If the expander is a EURO-
PSU, the D2+ terminal must not be connected to the I/O board.