9
ENFORCER V11 INSTALLATION GUIDE
CONNECTING THE CONTROL PANEL BATTERY
1. Unscrew the battery
compartment.
2. Connect the battery pack.
3. Close the battery compartment
making sure no battery cables
are trapped underneath.
IMPORTANT NOTE: The control panel back up battery must be replaced by the manufacturer’s
recommendation. The part code for this battery is BATT9V6/2Ah1-WE and is a NiMH 8 cell 2200mAh
rechargeable battery.
Install the batteries in the space provided and connect the battery connector to the three pins as shown
above.
Reinstall the battery holder cover and dispose of the batteries in accordance with the local regulations.
IMPORTANT INSTALLATION NOTES
Ensure wiring is done to the national wiring regulations in the country where the installation is taking place. In
the UK, this is BS 7671 Requirements for electrical installations; IET Wiring Regulations (17th edition). If in doubt,
consult a local qualified electrician.
Ensure that a readily accessible disconnect device (such as an un-switched fused spur or plug and socket
(with approved cover to prevent accidental disconnection from mains supply)) is incorporated in the premises’
installation wiring. It must be provided external to the equipment at a distance of 30mm minimum and is
connected as closely as possible to the supply.
Ensure that the Input Output Board (I/O Board) used to connect wired keypads, readers, inputs and outputs to the
Enforcer is only connected to circuits operating at SELV voltage.
When securing external wires, ensure that means are provided in the installation to prevent the SELV or signal
circuits from coming into contact with live parts of the power supply circuit. Wires should be fixed near their
terminal blocks.
The end of stranded conductor shall not be consolidated by soft soldering at places where the conductor is
subjected to contact pressure.
On completion of wiring use tie-wraps to prevent any loose wires causing a safety hazard (material of cables tie
shall be rated at least HB or better).
Cables ties and hoses shall be separate for power supply cable and SELV wirings.
Size of protective bonding conductors: minimum section 1.5mm².
Summary of Contents for ENFORCER V11
Page 1: ...Document SAP 102028845 01 ENFORCER V11 INSTALLATION GUIDE...
Page 16: ......