TECHNICAL SPECIFICATION
ELECTRICAL
European rated voltage
230V AC -15/+10%
European rated current
83mA
Capable operating voltage
90 - 264V AC
Current
222mA - 75mA
Rated frequency
50/60Hz
Zone fuse rating
T 2A (cannot replace)
PSU
Type A
Radio frequency
868MHz, FM Transceiver Narrow Band
ENFORCER BATTERY
Output instant voltage
11V (with no mains and battery fully charged)
Peak to peak ripple voltage
10mVpk
Battery low voltage cut off value
8.5V
Type
NiMH 8 cell 2200mAh rechargeable battery
CIE current when operating on battery backup
90mA
ENVIRONMENT
Physical dimensions (W x H x D)
220 x 160 x 50mm
Weight
1025g
Operating temperature
-10°C to +40°C
Nominal temperature
-10°C to +50°C
Storage temperature
-20°C to +60°C
I/O BOARD (IF CONNECTED)
Zones
2 Wired (DEOL, SEOL)
Output voltage
13.2 VDC (nominal)
Max current for PGM output
70mA
SAB outputs
250mA Continuous Load
Bus fuse
F500mA 250V Bus Fuse
Aux fuse
F500mA 250V Aux Fuse
SYSTEMS ANALYSIS: ZONES (MAX 66)
Wireless
32
Wired
2
Zone expansion modules
4 wired (8 wired zones each)
EURO-ZEM8, EURO-ZEM8+ or EURO-ZEM8+PSU
1 wireless (32 wireless zones)
EURO-ZEM32-WE