EURO 162/280 Installation Manual
Page: 14
EURO PCB Current Consumption
Environmental
Quiescent
75-90mA
Operational
-10°C to +40°C, Certified
User Code and Tag Guessing
Storage
-20°C to +60°C
4-digit codes
10,000
Humidity
75%
6-digit codes
100,000
Dimensions
Disallowed codes
None
Metal Casing
390 x 305 x 100mm
Weight: 6kg
All codes
16
12
According to EN50131-3:2009 Annex B
EURO Printed Circuit Board
150 x 175 x 30mm
According to spec of manufacturer of RFID
components used
EN50131 Grading
EURO 162 / 280
Grade
3
The below table is specifies ATS (Alarm Transmission System) performance criteria in
accordance with the requirements of EN50136-1-1.
Notification Equipment
Grade 2 Criteria
Option A
Option B
Option C
Option D
Remotely powered
external sounder
2 Optional
Optional Optional
Self-powered external
sounder
Optional 1 Optional Optional
Main Communication
Path (ATS)
ATS 2
ATS 2
ATS 2
ATS 3
Second Communication
Path (ATS)
Optional Optional ATS
1
Optional
Notification Equipment
Grade 3 Criteria
Option A
Option B
Option C
Option D
Remotely powered
external sounder
2 Optional
Optional Optional
Self-powered external
sounder
Optional 1 Optional Optional
Main Communication
Path (ATS)
ATS 4
ATS 4
ATS 4
ATS 5
Second Communication
Path (ATS)
Optional Optional ATS
3
Optional
When used with a supervised premises transceiver, options 'Grade 3 Option D' are supported. The use of
the Digi Modem restricts the options up to 'Grade 2 Option B'.
3.2
Important Installation Notes
Ensure wiring is done to the national wiring regulations in the country where the installation is
taking place. In the UK, this is BS 7671 Requirements for electrical installations; IET Wiring
Regulations (17th edition). If in doubt, consult a local qualified electrician.
Ensure that a readily accessible disconnect device incorporated in the premises installation wiring
shall be provided external to the equipment with a contact separation of at least 3,0mm and
connected as closely as possible to the supply. Example: Fused Spur Unit
When fixing external wires, ensure that means are provided in the installation to prevent the SELV
(Safety Electrical Low Voltage) or signal circuits from coming into contact with live parts of the
power supply circuit. Wires shall be fixed near their terminal blocks.
The end of stranded conductor shall not be consolidated by soft soldering at places where
the conductor is subjected to contact pressure. Example: Must not solder ends of wires which are
to be secured in detector and control panel terminal connectors.
On completion of wiring use tie-wraps to prevent any loose wires causing a safety hazard (material
of cables tie shall be rated at least HB or better).
Cables ties and hoses shall be separate for power supply cable and SELV (Safety Electrical Low
Voltage) wirings.
Size of protective bonding conductors: minimum section 1.5mm². Example: Electrical Earth wire
connections.