3.1
Technical Specification
Programmable
Outputs
Ratings
Normal State
Active State
Output 1
Relay, 3A, max 30V Normally Closed
Normally Open
Output 2
Relay, 3A, max 30V Normally Closed
Normally Open
Speaker
16 ohms
No tones
Repeat RKP tones & internal sounder
Strobe Output
500mA
12v
0v
Bell Output
500mA
12v
0v
ATE Outputs
2mA
5v
0v
All outputs are programmed in "CHANGE OUTPUTS" in the Engineer menu.
Input Resistance
1k / 1k DEOL Range
4k7 / 2k2 DEOL Range
4k7 / 4k7 DEOL Range
Normal
0k5 to 1k4
1k4 to 2k9
3k7 to 8k3
Burglary Alarm
1k5 to 5k9
4k2 to 7k8
8k4 to 10k2
Fault
6k to 8k1
8k to 11k3
10k3 to 14k9
Masking
8k2 to 17k
11k6 to 22k
15k to 22k
Tamper
<0k5 or >17k
<1k4 or >22k
<3k7 or >23k
All inputs are programmed in "CHANGE INPUTS" in the Engineer menu.
Fuses Value
Type
Bell fuse for bell terminals
F800mAL quick blow 250V
Glass
Auxiliary fuse for Aux terminals
F800mAL quick blow 250V
Glass
RS485 Bus Fuse for bus terminals
F800mAL quick blow 250V
Glass
Battery Fuse for battery terminals
T3.15A anti-surge slow blow 250V
Glass
iD Fuse for iD terminals
F800mAL quick blow 250V
Glass
230V Mains Fuse for mains terminals T500mA anti-surge slow blow 250V
Ceramic
Panel Power Supply Output
Nominal
Range
Output Voltage
13.7V DC
10-15V DC
Output Current
2.0A Continuous
2.5A peak, during battery charging
Power Supply Type A.
Maximum output peak ripple voltage: Max 100mV
SD Voltage which the deep discharge protection function will operate at: 10.5V
Over Voltage Protection Trigger Voltage: 18V
NOTE 1
. EURO power supplies are NOT designed for use with multiple batteries connected.
NOTE 2
. System load should not exceed the panel power supply output shown above, or the maximum load
supportable by the battery for the specified backup time, as in the table shown below.
NOTE 3
. The power ratings are based on battery shown in table – but ANY battery capable of supporting the
system load for the required time may be used without affecting these ratings.
Panel Power Supply Input
Nominal
Range
Mains Supply Voltage AC
230V AC at 50Hz
-15% +10%
Transformer Rating
45VA
18.5V at 2.5A
Battery Charging Specification
Float Voltage
13.8v DC
Current Limit
700mA
Battery low voltage cut off
10.5v
Standby battery capacity
7A to 17A
Recharge time
<24 Hours
EN50131-6:2008
Rated Output
In accordance with EN50131-6:2008, the EURO standby times and effective output currents depend on the
Security Grade
of the system and how 230V mains missing fault is signalled to the Alarm Receiving Centre.
Power supplies are rated in accordance with the requirements of EN50131-6, which are related to the maximum
battery size that can be accommodated in the housing and vary according to the grade of the system in which
they are installed, as per the following table:
Electrical Capability
EN50131-6 Rating. Maximum Load
Example Battery Model
Grade 2
Grade 3
Yuasa NP7-12
1.4A
0.9A
EN50131-1:2006+A1:2009 (30 hrs if notified to an ARC) for 17Ah battery = 477mA (Grade 3).
EN50131-1:2006+A1:2009 (60 hrs if not notified to an ARC) for 17Ah battery = 193mA (Grade 3) .