Copyright Pyroban Ltd. Issue 1 Page 12 of 32
Part number PM1083ENG
Operating the Vehicle
Once Gascheka duo is in the Drive mode
, the vehicle can be operated as normal but
the operator must be made aware of the potential for the vehicle to stop automatically (with or
without a delay).
Gascheka duo will activate vehicle shutdown if the flammable gas threshold is reached or a
system fault is detected.
Depending on the vehicle characteristics the shutdown may inhibit all vehicle functions
immediately or in some cases critical functions (e.g. power steering) may be preserved for a
period of time so that the vehicle may be brought to a controlled stop. A time delay of up to 25
seconds may be set via DIP switches in the Relay unit.
If such a delay is implemented, the vehicle will be labelled accordingly. In the event of a
shutdown the vehicle should be brought to a controlled stop BEFORE automatic shutdown
occurs. A shutdown or imminent delayed shutdown is identified by operation of the sounder and
a red triangle (on solid).
Refer to the original vehicle operator manual for further guidance on operating the vehicle.