PYD Electrobombas MOTOR 8 Series Operating And Maintenance Manual Download Page 9

1. After energising the motor for the first time, ensure that the starting current drops 

below the nameplate current within 4 seconds, which means that the motor has run at 

full speed. (If the motor is being started with a soft starter or an automatic transformer, 

the starting time should be less than 4 seconds).

2. Check the pump flow and pressure to ensure that the motor is running in the correct 

direction of rotation. Changing two of the three-phase power cables may change the 

direction of rotation.

3. While the motor is running for the first time check water for sand. If sand appears, 

continue pumping until the water disappears. If the motor is turned off while the pump is 

still pumping sand, this could build up in the pump and cause it to seize.

4. During the check or rotation check, it is necessary to monitor the number of starts and 

the time between starts. As a general rule, the motor should have 15 minutes to cool 

down between starts.

5. It is strongly recommended that the “Overcurrent” protection is set to decelerate to 

approximately 5% higher than the steady state current recorded when the motor/pump 

is started. It is not recommended that the “Over Current” protection is set just above the 

full load nameplate current as, in many cases, this will not protect the motor if the current 

increases, especially if the motor is not fully loaded. We believe that the operator needs 

to know if the current starts to rise, so that they can determine the cause.

6. All temperatures and all 3 phase voltage and current and insulation levels should be 

recorded during the life of the installation and monitored and checked as a form of pre-

ventative maintenance.

COMMISSIONING AND OPERATION

will lead to a large reduction in starting torque).

* The timers are set to ensure that the motor has sufficient voltage for long enough to run 

the motor as quickly as possible and also to bring the motor up to maximum voltage as 

quickly as possible as prolonged operation at reduced voltage will cause the motor win-

dings to be damaged.

* Thrust bearings in submersible motors will not operate properly at low rotational speeds. 

It is very important that the motor reaches at least 100% of rated speed to allow the thrust 

bearing to start working properly. This is especially a potential problem for motors being 

started with soft starters or operating on VWF drives.

www.proindecsa.com / [email protected]

MANUAL DE INSTALACIÓN Y MANTENIMIENTO

MOTOR PYD 8”

9

Summary of Contents for MOTOR 8 Series

Page 1: ...Por favor lea atentamente este manual antes del uso del equipo MANUAL DE INSTALACIÓN Y MANTENIMIENTO Serie MOTOR PYD 8 ...

Page 2: ...5 Verifique que el motor esté lleno con agua mezcla de anticongelante o agua limpia antes de la instalación EL NO ASEGURARSE DE QUE EL MOTOR ESTÁ LLENO DE AGUA ANTES DE FUNCIONAR ANULARÁ CUALQUIER RECLAMACIÓN DE GARANTÍA Asegú rese de que todos los tapones de llenado los tapones de drenaje las conexiones de los cables y los pernos de montaje estén apretados 6 El acoplamiento debe ser un ajuste des...

Page 3: ...lidad de agua del pozo El motor debe ser instalado con al menos 3 metros 10 pies entre la parte inferior del motor y la parte inferior del pozo 14 El motor se ha seleccionado correctamente para adaptarse a la bomba la carga de empuje de la bomba la capacidad de suministro eléctrico y la disponibilidad de agua del pozo El motor debe instalarse con al menos 3 metros entre la parte inferior del motor...

Page 4: ...no protegerá al motor si la co rriente aumenta especialmente si el motor no está completamente cargado Creemos que el operador necesita saber si la corriente comienza a aumentar para que puedan determinar la causa 6 Todas las temperaturas y las 3 fases de voltaje y corriente y los niveles de aislamiento deben ser registrados durante la vida de la instalación y monitoreados y revisados como una for...

Page 5: ...rados regu larmente con referencia a la temperatura del motor caliente o frío si el motor no tiene monitoreo de temperatura instalado Si el aislamiento frío cae por debajo de 50 megao hmios la instalación debe realizarse con cuidado 3 La presión de salida y el flujo de la bomba también deben ser monitoreados de ma nera regular 4 El rendimiento general de la bomba y el motor y el pozo puede ser rev...

Page 6: ...www proindecsa com proindecsa proindecsa com MANUAL DE INSTALACIÓN Y MANTENIMIENTO MOTOR PYD 8 6 ...

Page 7: ...he motor is filled with water antifreeze mixture or clean water prior to installation FAILURE TO ENSURE THAT THE ENGINE IS FILLED WITH WATER PRIOR TO OPERATION WILL VOID ANY WARRANTY CLAIMS Make sure all filler plugs drain plugs cable connections and mounting bolts are tight 6 The coupling must be a tight sliding fit on the shaft Do not tap or push the coupling onto the shaft this could damage the...

Page 8: ...tor has been properly selected to suit the pump the thrust load of the pump the power supply capacity and the water availability of the well The motor should be installed with at least 3 metres between the bottom of the motor and the bottom of the well supply capacity and the water availability of the well The motor must be installed with at least 3 meters 10 feet between the bottom of the motor a...

Page 9: ...d It is not recommended that the Over Current protection is set just above the full load nameplate current as in many cases this will not protect the motor if the current increases especially if the motor is not fully loaded We believe that the operator needs to know if the current starts to rise so that they can determine the cause 6 All temperatures and all 3 phase voltage and current and insula...

Page 10: ...ecorded regularly with refe rence to the motor temperature hot or cold if the motor does not have temperature monitoring installed If the cold insulation drops below 50 megohms the installation should be carried out with care 3 Outlet pressure and pump flow should also be monitored on a regular basis 4 The overall performance of the pump and motor and the well can be reviewed based on the informat...

Page 11: ...www proindecsa com proindecsa proindecsa com MANUAL DE INSTALACIÓN Y MANTENIMIENTO MOTOR PYD 8 11 ...

Page 12: ...hms avant le fonctionnement et d au moins 50Mohm à chaud après le fonctionnement 5 Vérifiez que le moteur est rempli d un mélange eau antigel ou d eau propre avant l ins tallation Assurez vous que tous les bouchons de remplissage les bouchons de vidan ge les connexions de câbles et les boulons de montage sont bien serrés 6 L accouplement doit être bien ajusté sur l arbre Ne tapez pas ou ne poussez...

Page 13: ...e l alimentation électrique et de la disponibilité de l eau dans le puits Le moteur doit être installé avec au moins 3 mètres 10 pieds entre le bas du moteur et le fond du puits 14 Le moteur a été choisi en fonction de la pompe de la charge de poussée de la pompe de la capacité de l alimentation électrique et de la disponibilité de l eau dans le puits Le moteur doit être installé avec au moins 3 m...

Page 14: ...é Nous pensons que l opérateur doit savoir si le courant commence à augmenter afin de pouvoir en déterminer la cause 6 Toutes les températures et toutes les tensions et courants triphasés ainsi que les niveaux d isolation doivent être enregistrés pendant la durée de vie de l installation puis surveillés et contrôlés dans le cadre d une maintenance préventive Il n y a pas de roulements à billes qui...

Page 15: ...ment l isolation de l enroulement du moteur et du fil de descente en fonction de la température du moteur chaude ou froide Si l isolation froide descend en dessous de 50 mégohms l installation doit être réalisée avec précaution 3 La pression de sortie et le débit de la pompe doivent également être contrôlés régu lièrement 4 Les performances globales de la pompe et du moteur ainsi que du puits peuv...

Page 16: ...www proindecsa com proindecsa proindecsa com MANUAL DE INSTALACIÓN Y MANTENIMIENTO MOTOR PYD 8 16 ...

Page 17: ...ga en cuenta que los productos eléctricos baterías o cables no deben desecharse junto con la basura doméstica Recicle donde existan instalaciones adecuadas para ello consulte con su autoridad local para obtener consejos de reciclaje El abandono o la eliminación incontrolada de residuos puede causar daños al medio ambiente y a la salud humana Por lo que al reciclar este producto de manera responsab...

Page 18: ... proindecsa proindecsa com INSTRUCTIONS D UTILISATION ET MAINTENANCE MOTEUR PYD 8 18 Polígono Indsutrial Oeste parc 25 12 30169 San Ginés Murcia Tlf 968 88 08 52 Fax 968 09 84 www proindecsa com proindecsa proindecsa com ...

Reviews: