6.
CO-OPERATION WITH THE PX277 CONFIGURATOR
Lamp settings can be changed by connecting the PX277 PxArt Settings Controller configurator.
At the moment of connection, the PX390 starts again which causes LEDs to be off for a while and
the diode indicating the DMX signal condition pulses for 2 seconds.
When the device is turned on, its name appears on the display. The main menu allows a preview
of many lamp parameters from PxArt series and a change of the following options: colour and
brightness address, scene brightness and colour, colour inversion, smoothing, change of
smoothing time, Flicker free and restoration of default parameters.
Furthermore, it is possible to check the lighting time and lamp operation time (total lamp operation
time, also without switching the diodes off). Additionally, information concerning minimum,
maximum and current temperature reached by the lamp is displayed.
PxArt Settings Controller also allows for checking the version number of the software which is
installed in the lamp, its serial number and model.
Navigating through the menu is possible with programmer buttons located below the display. The
"escape" button allows an exit to the upper level in the device menu; "next" and "previous" buttons
make it possible to go forward and backward (alternatively value decreasing or increasing).
However, the "enter" button allows you to enter the edition of the selected menu or to confirm the
edited value.
Lamp
parameter value
DMX signal value
Colour temperature
adjustment (Lamp colour)
Brightness adjustment
(Lamp brightness)
4500K
100%
3600K
50%
255
255
2700K
128
0
0%
128
0
Setting lamp parameters
-
DMX signal value:
8
Invert colour
Turning off
Invert colour
Turning on
0
128
255