background image

3

1. GENERAL DESCRIPTION

2. SAFETY CONDITIONS

PX254 LED Driver 3 x 6A OC is a device powered with safe voltage 12-24 V; however, during its 

installation and use the following rules must be strictly observed:

1. The device may only be connected to 12 - 24 V DC with current-carrying capacity compatible 

with technical data.

2. All the conductors should be protected against mechanical and thermal damage.

3. In the event of damaging any conductor, it should be replaced with a conductor of the same 

technical data.

4. Connection of power supply can only be made with a conductor of minimum cross-section area 

2

of 2,5mm  and DMX signal with shielded conductor.

5. All repairs and connections of outputs or DMX signal can only be made with cut off power 

supply.

6. PX254 should be strictly protected against contact with water and other liquids.

7. All sudden shocks, particularly dropping, should be avoided.

8. The device cannot be turned on in places with humidity exceeding 90%.

9. The device cannot be used in places with temperature lower than 2°C or higher than 40°C. 

10. Clean with damp duster only.

PX254 driver is designed to control the LEDs. Built-in DMX receiver allows to control 3 DMX 

channels (R, G, B) directly with the DMX protocol. Wide range of power supply voltage and high 

current carrying capacity outputs (6A) permit a control of large quantities of LEDs. What is more 

the PX254 has built-in fuses that can be replaced by the user by himself. 

PX254 can be either controlled by DMX, and act independently. In this case, the user is offered a 

fully programmable scene and 18 pre-programmed sequences, which can also freely change the 

playback speed and fluidity changes in steps. By using 16-bit resolution control of each channel 

is completely smooth. In addition, the PX254 driver gained control mode called effect mode to 

control the programs built into the driver and the simultaneous change the settings of parameters 

such as speed, brightness and fade using DMX-512 signal sent from the external controller.

The driver has a built-in tuning frequency signal system ("flicker free" technology), which makes it 

particularly useful in applications for the television industry. The RGB LEDs often differ quite 

substantially in parameters, this can cause problems in obtaining a white color (at full power 

especially). Therefore PX254 comes with a very useful function called "white balance". Thanks to 

it you can choose color correction for each set of LEDs controlled by the device to achieve at full 

power the color white. What's more, this feature also allows you to adjust the color temperature of 

white color.

The  PX254  is  produced  in  common  anode  version  -  it  allows  LEDs  connection  on  common 

anode.

Summary of Contents for PX254

Page 1: ...MANUAL LED Driver 3 x 6A OC PX254 R...

Page 2: ...No DMX signal response 12 Description of programs 13 Light control frequency 14 Screen saving screen blanking 15 Smooth 16 Default settings and memory error Err 17 RDM 18 Programming 19 Connections sc...

Page 3: ...r supply voltage and high current carrying capacity outputs 6A permit a control of large quantities of LEDs What is more the PX254 has built in fuses that can be replaced by the user by himself PX254...

Page 4: ...GB LIGHTNESS COLOUR etc no DMX signal response method selection MASTER SLAVE mode settings LIGHTNESS COLOUR control mode RGB control mode setting parameters for all channels simultaneously V 3 2 1 4 5...

Page 5: ...ignal LED blanking MASTER mode on off DMX address settings for first channel 5 DMX ADDRESS SETTING The menu of the PX282 driver allows for setting the DMX address within a range between 1 and 506 511...

Page 6: ...up on a display To choose the number of emitted DMX channels in the Con section press the next key The Chn will show up on the display ENTER ENTER ENTER NEXT NEXT NEXT The on option stands for turning...

Page 7: ...byte allows for setting each colour individually R red G green B blue and on the fourth channel the Dimmer function is implemented dimming all outputs In the 3 channel mode 3 byte each colour R G B c...

Page 8: ...ontrol a given parameter of a selected mode EFF mode effect channels desription CHANNEL1 RED CHANNEL2 GREEN CHANNEL3 BLUE CHANNEL5 SPEED CHANNEL6 FADE CHANNEL7 BRIGHTNESS x x x x x x x x x x x x x x x...

Page 9: ...unction is to control the lightness of one colour LEDs connected to all outputs In this example the same address must be assigned to all channels so that all outputs are controlled by one slider on th...

Page 10: ...5 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 255 255 0 0 0 0 0 255 255 255 The following tables show the...

Page 11: ...nter Similarly select oFF to turn off the function 1 2 ENTER The Frq function allows for setting the basic control frequency for the LEDs This function is extremely useful in applications for the tele...

Page 12: ...n the DMX signal packets for the selected option or the time interval set in the menu NEXT NEXT ENTER The smoothing function may slightly slow down the lamp s response rate to changes in the DMX signa...

Page 13: ...Please note that all set parameters of the PX254 device after restoring the default settings will be changed to those shown below DMX address 1 driver operating mode RGB 3b 3 byte master mode off numb...

Page 14: ...alue 0x01 STATUS_MESSAGES information about device status PID 0x0030 DEVICE_MODEL_DESCRIPTION device description e g name PID 0x0080 MANUFACTURER_LABEL e g name of manufacturer PID 0x0081 DEVICE_LABEL...

Page 15: ...X282 PID 0x801F Editable parameter Similarly as in the subsection above SCREENSAVER_ON OFF settings of screensaver display backlight in PX282 PID 0x8024 Editable parameter With the 0 value display bla...

Page 16: ...allows for moving backward within the selected menu 16 NEXT NEXT ENTER ENTER NEXT NEXT NEXT ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT N...

Page 17: ...line With this solution applied there is no limitation of number devices that can be connected to the DMX controller connected in series Connections must be made using cables of suitable thickness Pr...

Page 18: ...kg 175 mm 43 mm 27 mm including terminal block DMX channels power supply current consumption no load current consumption output channels number control accuracy programmable scenes built in programs o...

Page 19: ...k upnik Name of producer Manufacturer s address We declare that our product Product name Product code complies with the following standards LVD EMC Additional information Krak w 15 07 2014 DECLARATION...