13
16. DEFAULT SETTINGS AND MEMORY ERROR (Err)
The device has a feature that allows for restoring default settings.
To use this option, PX254 must be disconnected from the power supply. Before restoring the
power, press and hold the „previous” button. After turning the device on, the message will
appear on the screen (when turning on the power until displaying the previous message,
the
„
previous” button must be pressed).
This menu designation restores default settings. Accepting this message by pressing the „enter”
key restores default settings. It is also possible to exit this menu without returning to default
settings by pressing the „escape” key.
ź
Please note that all set parameters of the PX254 device after restoring the default settings will
be changed to those shown below:
ź
DMX address - 1,
ź
driver operating mode - RGB (3b - 3-byte),
ź
master mode - off,
ź
number of sent DMX channels - 128,
ź
white balance - off
ź
no signal operating mode - Program 1
ź
smoothing function (smooth) - off
ź
temperature limitation - off
The device is equipped with a built-in memory work control function.
If there are problems with the memory operation on the PX254 display, the message
appears - memory error.
In this situation, select the “enter” key. The device will reload the default configuration and upload
it to the memory. If after this operation, the message remains on the screen, the memory is
permanently damaged and the unit must be sent to the service point.
Err message - memory error
ENTER
POWER ON
PRESSED PREVIOUS
BUTTON
ESCAPE