background image

13. LIGHT CONTROL FREQUENCY

11

14. SCREEN SAVING (SCREEN BLANKING)

The device is equipped with a feature that allows for turning off the backlight. This option is 
marked with the 

SCr

 sign. With this feature, the display is turned off after 5s (if the keys of the 

device are not pressed). Of course, the device continues its operation without interfering with 
other parameters. Press any key to restore the backlight.

1

2

ENTER

ENTER

NEXT

4x

NEXT

To activate the screen saving feature:

1. Set the 

SCr 

function and confirm the selection by pressing 

enter

.

2. Use the 

next

 or 

previous

 buttons to change the value to 

on

 and confirm the 

selection by pressing 

enter

.

Similarly, select "oFF" to turn off the function.

1

2

ENTER

The

 Frq

 function allows for setting the basic control frequency for the LEDs. This function is 

extremely  useful  in  applications  for  the  television  industry.  By  applying  the  "flicker  free" 
technology, it is possible to avoid the unpleasant flickering effect which is caused by improper 
signal synchronization that controls the LEDs. The user can choose from the available frequency 
range from 366 Hz up to 1.5 kHz which can be smoothly changed using the 

previous 

or 

next 

buttons and selecting a different value.
The frequency value in the upper range (e.g. 1.50 = 1.5 kHz) helps avoid the flickering effects that 
are visible in video cameras.

To set the selected range of basic frequencies:

1. Set the 

Frq

 function.

2. Set the selected value using the „next”

 

or „previous” buttons.

ENTER

NEXT

3x

NEXT

Summary of Contents for PX254

Page 1: ...MANUAL LED Driver 3 x 6A OC PX254 R...

Page 2: ...No DMX signal response 12 Description of programs 13 Light control frequency 14 Screen saving screen blanking 15 Smooth 16 Default settings and memory error Err 17 RDM 18 Programming 19 Connections sc...

Page 3: ...r supply voltage and high current carrying capacity outputs 6A permit a control of large quantities of LEDs What is more the PX254 has built in fuses that can be replaced by the user by himself PX254...

Page 4: ...GB LIGHTNESS COLOUR etc no DMX signal response method selection MASTER SLAVE mode settings LIGHTNESS COLOUR control mode RGB control mode setting parameters for all channels simultaneously V 3 2 1 4 5...

Page 5: ...ignal LED blanking MASTER mode on off DMX address settings for first channel 5 DMX ADDRESS SETTING The menu of the PX282 driver allows for setting the DMX address within a range between 1 and 506 511...

Page 6: ...up on a display To choose the number of emitted DMX channels in the Con section press the next key The Chn will show up on the display ENTER ENTER ENTER NEXT NEXT NEXT The on option stands for turning...

Page 7: ...byte allows for setting each colour individually R red G green B blue and on the fourth channel the Dimmer function is implemented dimming all outputs In the 3 channel mode 3 byte each colour R G B c...

Page 8: ...ontrol a given parameter of a selected mode EFF mode effect channels desription CHANNEL1 RED CHANNEL2 GREEN CHANNEL3 BLUE CHANNEL5 SPEED CHANNEL6 FADE CHANNEL7 BRIGHTNESS x x x x x x x x x x x x x x x...

Page 9: ...unction is to control the lightness of one colour LEDs connected to all outputs In this example the same address must be assigned to all channels so that all outputs are controlled by one slider on th...

Page 10: ...5 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 255 255 0 0 0 0 0 255 255 255 The following tables show the...

Page 11: ...nter Similarly select oFF to turn off the function 1 2 ENTER The Frq function allows for setting the basic control frequency for the LEDs This function is extremely useful in applications for the tele...

Page 12: ...n the DMX signal packets for the selected option or the time interval set in the menu NEXT NEXT ENTER The smoothing function may slightly slow down the lamp s response rate to changes in the DMX signa...

Page 13: ...Please note that all set parameters of the PX254 device after restoring the default settings will be changed to those shown below DMX address 1 driver operating mode RGB 3b 3 byte master mode off numb...

Page 14: ...alue 0x01 STATUS_MESSAGES information about device status PID 0x0030 DEVICE_MODEL_DESCRIPTION device description e g name PID 0x0080 MANUFACTURER_LABEL e g name of manufacturer PID 0x0081 DEVICE_LABEL...

Page 15: ...X282 PID 0x801F Editable parameter Similarly as in the subsection above SCREENSAVER_ON OFF settings of screensaver display backlight in PX282 PID 0x8024 Editable parameter With the 0 value display bla...

Page 16: ...allows for moving backward within the selected menu 16 NEXT NEXT ENTER ENTER NEXT NEXT NEXT ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT N...

Page 17: ...line With this solution applied there is no limitation of number devices that can be connected to the DMX controller connected in series Connections must be made using cables of suitable thickness Pr...

Page 18: ...kg 175 mm 43 mm 27 mm including terminal block DMX channels power supply current consumption no load current consumption output channels number control accuracy programmable scenes built in programs o...

Page 19: ...k upnik Name of producer Manufacturer s address We declare that our product Product name Product code complies with the following standards LVD EMC Additional information Krak w 15 07 2014 DECLARATION...

Reviews: