background image

!

PID: 0x801A

Editable parameter.

 At 0 value Smooth is turned off, for a value of 1

Smooth mode is set to a Packet to Packet (P2P) and for the value of 2 Smooth is in
time mode (TIM-description in 14th point). The default value is 0 - Smooth off; 

!

 SMOOTH_TIME – Smooth time for TIM function chosen in subsection above  - 

PID: 0x801B, Editable parameter

. Unit in [ms]. Minimal value of this parameter is 

10 and maximal 999 [ms]. Default value is 200. 

!

 NO_SIG_P1-18|SC_19|ON_20|OFF_21 - choice of work mode for No DMX signal - 

PID: 0x801C

Editable parameter

. Minimal Value is 1, maximal 21. For values 1-18 

menu allows to chose program from 1 to 18 which is played during no DMX signal 
detection. For the 19 value a scene saved in memory is set and for the 20 value all 
outputs are set to ON with maximum value. The value 21 sets to OFF all outputs 
during time with no DMX signal received. Default value is 21; 

!

 SCENE_RED - settings of red channel value for scene saved in PX282 - 

PID: 0x801D, Editable parameter

. Minimal value is 0, maximal 255 (maximal 

brightness). By defualt value set to 255;

!

 SCENE_GREEN - settings of green channel value for scene saved in PX282 - 

PID: 0x801E, Editable parameter

. Similarly as in the subsection above;

!

 SCENE_BLUE - settings of blue channel value for scene saved in PX282 - 

PID: 0x801F, Editable parameter.

 Similarly as in the subsection above;

!

 SCREENSAVER_ON/OFF -  settings of screensaver (display backlight in PX282) - 

PID: 0x8024

Editable parameter

. With the 0 value display blanking is not active, 

the 1 value means screensaver active. Default value is 0;

 SMOOTH_DIS_0/P2P_1/TIM_2 - the choice of options relating to the Smooth function - 

15

ź

 

PID: 0x8025, Editable parameter.

 Minimum value is 1 and maximal 999 (maximum 

speed). By default it is set to 10. Value 1 represents 0,1s, and 999 - 99,9s;

ź

 PROGRAM_FADE - settings of smooth transition between following steps of a program -

PID 0x8026, Editable parameter.

 The minimum value is 0 (step transition) a 

maximum of 100 (transition completely smooth). The default value is 100;

ź

  BALANCE ON / OFF - to activate or deactivate the balance of output channels - 

PID 0x8027, Editable parameter.

 A value of 0 is a balance off, a value of 1 active 

balance. The default value is set to 0;

ź

  PWM_FREQENCY - LEDs refresh frequency - 

PID 0x8028, Editable parameter. 

The minimum value is 366 and the maximum is 25000. The unit is [Hz] and the 
default value is 366.

ź

 SERIAL_NUMBER - device serial number - 

PID: 0x8030

Editable parameter

The minimum value is 0, and the maximum is 4294836225. The default value is 0.

PROGRAM_SPEED - programs playback speed settings (playing next steps of program) - 

ź

 DISPLAY_FLIP - inverting the meter display 180 degrees - 

PID: 0x8031

Editable 

parameter

. The minimum value is 0, and the maximum is 1. The default value is 0.

Summary of Contents for PX254

Page 1: ...MANUAL LED Driver 3 x 6A OC PX254 R...

Page 2: ...No DMX signal response 12 Description of programs 13 Light control frequency 14 Screen saving screen blanking 15 Smooth 16 Default settings and memory error Err 17 RDM 18 Programming 19 Connections sc...

Page 3: ...r supply voltage and high current carrying capacity outputs 6A permit a control of large quantities of LEDs What is more the PX254 has built in fuses that can be replaced by the user by himself PX254...

Page 4: ...GB LIGHTNESS COLOUR etc no DMX signal response method selection MASTER SLAVE mode settings LIGHTNESS COLOUR control mode RGB control mode setting parameters for all channels simultaneously V 3 2 1 4 5...

Page 5: ...ignal LED blanking MASTER mode on off DMX address settings for first channel 5 DMX ADDRESS SETTING The menu of the PX282 driver allows for setting the DMX address within a range between 1 and 506 511...

Page 6: ...up on a display To choose the number of emitted DMX channels in the Con section press the next key The Chn will show up on the display ENTER ENTER ENTER NEXT NEXT NEXT The on option stands for turning...

Page 7: ...byte allows for setting each colour individually R red G green B blue and on the fourth channel the Dimmer function is implemented dimming all outputs In the 3 channel mode 3 byte each colour R G B c...

Page 8: ...ontrol a given parameter of a selected mode EFF mode effect channels desription CHANNEL1 RED CHANNEL2 GREEN CHANNEL3 BLUE CHANNEL5 SPEED CHANNEL6 FADE CHANNEL7 BRIGHTNESS x x x x x x x x x x x x x x x...

Page 9: ...unction is to control the lightness of one colour LEDs connected to all outputs In this example the same address must be assigned to all channels so that all outputs are controlled by one slider on th...

Page 10: ...5 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 255 255 0 0 0 0 0 255 255 255 The following tables show the...

Page 11: ...nter Similarly select oFF to turn off the function 1 2 ENTER The Frq function allows for setting the basic control frequency for the LEDs This function is extremely useful in applications for the tele...

Page 12: ...n the DMX signal packets for the selected option or the time interval set in the menu NEXT NEXT ENTER The smoothing function may slightly slow down the lamp s response rate to changes in the DMX signa...

Page 13: ...Please note that all set parameters of the PX254 device after restoring the default settings will be changed to those shown below DMX address 1 driver operating mode RGB 3b 3 byte master mode off numb...

Page 14: ...alue 0x01 STATUS_MESSAGES information about device status PID 0x0030 DEVICE_MODEL_DESCRIPTION device description e g name PID 0x0080 MANUFACTURER_LABEL e g name of manufacturer PID 0x0081 DEVICE_LABEL...

Page 15: ...X282 PID 0x801F Editable parameter Similarly as in the subsection above SCREENSAVER_ON OFF settings of screensaver display backlight in PX282 PID 0x8024 Editable parameter With the 0 value display bla...

Page 16: ...allows for moving backward within the selected menu 16 NEXT NEXT ENTER ENTER NEXT NEXT NEXT ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT N...

Page 17: ...line With this solution applied there is no limitation of number devices that can be connected to the DMX controller connected in series Connections must be made using cables of suitable thickness Pr...

Page 18: ...kg 175 mm 43 mm 27 mm including terminal block DMX channels power supply current consumption no load current consumption output channels number control accuracy programmable scenes built in programs o...

Page 19: ...k upnik Name of producer Manufacturer s address We declare that our product Product name Product code complies with the following standards LVD EMC Additional information Krak w 15 07 2014 DECLARATION...

Reviews: