The user may use the following editable parameters:
•
Fade rate – range 1 – 15;
The number of steps needed to achieve the maximum level of
brightness
•
Fade time – range 0 – 15;
The transition time between the levels of brightness:
◦
0 – immediate transition between brightness levels
◦
1 – 15 time of transition
•
Power On level – range 0 – 254;
The brightness of the lamp after switching on:
◦
0 – light is off
◦
254 – full brightness (100%)
•
System error level – range 0 – 254;
The brightness level of the lamp when on the control bus there is an
error:
◦
0 – light is off
◦
254 – full brightness (100%)
•
Minimal level – range 0 – 254;
The lowest level of the brightness of the lamp:
◦
0 – light is off
◦
254 – full brightness (100%)
When this parameter is set to a relatively high level, the DMX
control will respond during reducing of the modulation only to this
value. After crossing of minimal level the further reduction will not
affect the behavior of the lamp.
11