Assemble Sections
1)
Hold the fluid section in one hand then press the disconnect bar (7) into the fluid
body (1) using your thumb. Once depressed, the motor, coupling, and auger (16,
17, 14) assembly can be inserted through the syringe support bracket (8) and back
into the fluid body.
2)
Once the motor assembly (16, 17, 14) has been seated on the inside bottom of the
fluid body (1) the disconnect bar can be released to lock the assembly in place.
Note: You may need to press & wiggle the motor in place to allow the disconnect
bar to retract locking the assembly in place.
Spare Parts
PVA offers standard spare parts kits for all dispensing valves. These kits are
stocked for immediate shipment and allow replacement of all wearable parts of the valve.
The spare parts kit for the SV200, product number
SV2-08-SP or SV2-16-SP
,
include the following components:
The
08 or 16
are used to specify the auger type.
Kit Includes:
Qty Part
Number
Description
1
Auger
Pitch
- 114-2514
8
pitch
- V503-16
16
pitch
1 V504
Luer
Adapter
3 V511
O-Ring
5 V507
Feed
Tube
2
V004
Allen Key, 0.9 mm
Summary of Contents for SV200