![PVA SV200 Operation Manual Download Page 6](http://html.mh-extra.com/html/pva/sv200/sv200_operation-manual_1628577006.webp)
End of Day Cleaning & Maintenance
The SV200 valve is designed with a quick connect feature to allow ease of
cleaning and disassembly of the wetted section of the valve on a daily basis. A spare parts
kit, part #
SV2-08-SP or SV2-16-SP,
is available with all the normal wear parts included.
1)
Begin disassembly by disconnecting the motor cable (23) and syringe air adapter
from the valve assembly.
2)
Disconnect the syringe of fluid from the feed tube (20).
3)
Remove the feed tube (20) from the fluid body (1) and discard.
Note: The tapered plastic fitting of the feed tube is press fit into the fluid body.
4)
Hold the valve body in one hand and press the disconnect bar (7) into the fluid
body (1) using your thumb. At the same time using your other hand, grab the top
of the servo motor (16) and pull the motor with coupling (17) and auger (14)
assembly out of the fluid section to completely remove it from the valve.
Note: There will be a spring force against the disconnect bar to force it away from
the fluid body.
5)
Using a cloth, clean all material from the auger (14).
6)
Then using a q-tip or other cleaning utensil wipe the luer adapter (15) and fluid
body (1) clean of all material.
7)
Once the valve is clean it can be reassembled by again in one hand, hold the fluid
section and press the disconnect bar (7) into the fluid body (1). Once depressed,
the motor, coupling, and auger (16, 17, 14) assembly can be inserted back into the
fluid body.
8)
Once the motor assembly (16, 17, 14) has been seated on the inside bottom of the
fluid body (1) the disconnect bar can be released to lock the assembly in place.
Note: You may need to press & wiggle the motor in place to allow the disconnect
bar to retract locking the assembly in place.
Complete Valve Disassembly
Cleaning and rebuilding the entire valve will be required from time to time. A
spare parts kit, part #
SV2-08-SP or SV2-16-SP
is available with all the normal wear
parts included.
1)
Begin disassembly by disconnecting the motor cable (23) and syringe air adapter
from the valve assembly.
2)
Disconnect the syringe of fluid from the feed tube (20).
3)
Remove the feed tube (20) from the fluid body (1) and discard.
Note: The tapered plastic fitting of the feed tube is press fit into the fluid body.