Installation Guide / PostMount 3-A for XL Panels
7
Code-Compliant Planning and Installation Guide V 1.1 - Complying with AS/NZS1170.2-2011 ADMT 4-2016
- Installation Instruction -
Note:
1: Adjust the angle of the allation, the angle of the Rectangular
Tube-Master with 10° (6 holes from up to bottom corresponds to
10° to 60° tilt angle) in order to make the assembly process run
smooth.
2: Using the adjustable washer to avoid the gap between the
Rectangular Tube-Master and the Adjustable Tube. Unreliable
connection is forbidden.
1) Fix the Rectangular Tube-Master at Steel Cap Assembly with
M14*120 hex bolt, M14 nut, plain washer 14, and spring washer 14.
See the mark (1).
20 Fix the Adjustable Tube at Rectangular Tube- Master with
M14*120 hex bolt , plain washer 14, and spring washer 14, M14 nut.
See the mark (2).
3) Fix the Adjustable Tube at Steel Cap Assembly with M14*120 hex
bolt, M14 nut, plain washer 14, and spring washer 14.
See the mark (3).
Realized the angle adjustment by position the bolt in the differrent
holes.
4) Fasten the Steel Cap Assembly to Pipe with M14*150, M14*110 Hex
Bolt, keep the Rectangular Tube-Master parallel to the south-north
by adjust the Steel Cap Assembly.
Recommended torque for M14 bolts is 95~100 N·m.
3. Rectangular Tube-Master and Adjustable Tube
Installation