Installation Guide / PostMount 3-A for XL Panels
10
Code-Compliant Planning and Installation Guide V 1.1 - Complying with AS/NZS1170.2-2011 ADMT 4-2016
Note:
The Universal Clamp can be used both as a End Clamp and a Inter Clamp, and the height can be adjusted from 30 to
46 mm.
When the side of the Universal Clamp close the narrow side of the Universal Clamp Buckle, it can be used as End
Clamp, and when the side of the Universal Clamp close the wide side of the Universal Clamp Buckle, it can be used as
Inter Clamp, as shown in the figure below.The Universal Clamp can be directly rotated to the position of required End
or Inter Clamp.
Recommended torque for M8 bolts when it is Inter Clamp is 18~20 N·m.
Recommended torque for M8 bolts when it is End Clamp is 13~14 N·m.
Apply one pre-assembled Grounding Lug per Rail. Click the Grounding Lug into to the rail channel and insert the
Copper Wire. (the maximum size is 4 mm
2
or similar) Fasten the bolt M6*14 with 5~6 N·m and the bolt M8*25 with 16~20
N.m .Copper Pipe will be supplied for the case that using small size Copper Wire.