3.4 Pneumatic Connection
The
AFD92
Adjustable Force Devices require a dry, non-lubricated, 5
m filtered, 80 psi
(5.5 Bar) maximum air supply. Failure to provide supply air to these specifications can
degrade performance and will void any warranty repairs concerning pneumatic
components. Filtered air is required to prevent foreign material from entering the AFD.
The pneumatic supply system should be configured as shown in Figure 4.
Figure 4. Pneumatic configuration
To apply force in the po direction, on an AFD91 or AFD92, a Supply Line must be
connected to the + Supply Air Port. To apply force in the negative - direction, on an
AFD92, a Supply Line must be connected to the - Supply Air Port.