Before Installation
Professional Installation Required
•
Installation requires shutting water off to home, cutting home water supply pipe
and using a welding torch to add piping and fittings. Specialized tools and skills are
required. Not a do-it-yourself type of project.
Make Sure Your Water Has Been Thoroughly Tested
•
An analysis of your water should be made prior to the selection of your water
conditioning equipment. Your dealer will generally perform this service for you, and
may send a sample to the factory for analysis and recommendations. Enter your
analysis information on page 4 for your permanent record.
•
The Multitrol System is designed to reduce tannis, iron, manganese and hardness.
Contact Puretec when selecting model and regeneration settings for best results.
Install Water Conditioning Equipment Correctly
•
Select the location of your Multitrol system with care. Various conditions which
contribute to proper location are as follows:
•
Install as close as possible to a drain
•
Install in correct relationship to other water treatment equipment. Contact Puretec
for assistance.
•
Install the Multitrol system in the supply line BEFORE the water heater.
Temperatures above 110°F (43.3°C) will damage the system and void the warranty.
•
DO NOT install the Multitrol system in a location where freezing temperatures occur.
Freezing may cause permanent damage and will also void the warranty.
•
DO NOT install where water hammer conditions may occur without installing an
arrestor
•
Allow sufficient space around the installation for easy servicing. Provide a non-
switched 240V power source for the control valve.
Pre-installation