PROBLEM
POSSIBLE CAUSE
SOLUTION
Error Code - 1003
Control valve motor ran too long and was
unable to find the next cycle position
A. Motor failure during regeneration
A. Check motor connections. Perform a 'dry'
reset
B. Foreign material lodged in valve
B. Clean/replace piston/spacer stack assembly.
Perform a 'dry' reset
C. Drive bracket not correctly installed
C. Snap drive bracket in correctly. Perform a
'dry' reset.
Error Code - 1004
Control valve motor ran too long and timed out
trying to reach home position
A. Drive bracket not correctly installed
A. Snap drive bracket in correctly. Perform a
'dry' reset.