SMC4-4-16A16B.
Four-axis motion controller
Edition of 03.08.2016
25
www.purelogic.ru
8 (800) 555 63 74
Case: (coordinates (20.0), (20.20), (0.20), (0,0) four drill holes 5mm in depth, the two safety plane, and one second stay at the hole bottom, a speed of
200)
G0X0Y0Z5
G82X20YOR2Z-5P1000F200
G82X20Y20R2Z-5P1000F200
G82X0Y20R2Z-5P1000F200
G82X0Y0R2Z-5P1000F200
G0X0Y0Z5
G83: (canned cycle drilling instruction)
Format: G83X .. Y. Z. R. I. F....
X, Y represent end coordinates, Z represents the depth of processing,I represents the displacement of each fall,it will be cut back action When
processed to I depth.
F processing speed
R represents the beginning of the start plane and said Z end after returned
M107 corresponds OUT_7 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M108 corresponds OUT_8 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M109 corresponds OUT_9 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M110 corresponds OUT_10 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M111 corresponds OUT_11 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M112 corresponds OUT_12 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M113 corresponds OUT_13 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M114 corresponds OUT_14 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M115 corresponds OUT_15 Output High Level (artificially high, Facilitate different voltage connect pull-up resistor)
M116 Because logic easy to confuse, so give up on the OUT_16 Output Control
M210 corresponding OUT_10 output low level (perfusion 500ma to ground)
M211 corresponding OUT_11 output low level (perfusion 500ma to ground)
M212 corresponding OUT_12 output low level (perfusion 500ma to ground)
M213 corresponding OUT_13 output low level (perfusion 500ma to ground)
M214 corresponding OUT_14 output low level (perfusion 500ma to ground)
M215 corresponding OUT_15 output low level (perfusion 500ma to ground)
M216 Because logic easy to confuse, so give up on the OUT_16 Output Control
M201 corresponding OUT_1 output low level (perfusion 500ma to ground)
M202 corresponding OUT_2 output low level (perfusion 500ma to ground)
M203 corresponding OUT_3 output low level (perfusion 500ma to ground)
M204 corresponding OUT_4 output low level (perfusion 500ma to ground)
M205 corresponding OUT_5 output low level (perfusion 500ma to ground)
M206 corresponding OUT_6 output low level (perfusion 500ma to ground)