PUREGAS, LLC
P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 76 of 79
P012649 – Rev B
14.2 Set Point Limits and Defaults
14.2.1
System Adjustments
14.2.2
Alarm Set Points
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
Shutdown
Low Outlet Pressure
Alarm
1.0 9.5 6.5 PSI
High Humidity Alarm
10.0 % YES
Excessive Compressor
Run Time Alarm
1.0 10.0 3.0 Minutes
14.2.3
System Operations
Description
ON Value
OFF Value
Default
Value
Unit of
Measurement
Compressor 20.0
50.0
PSI
Fan 85.0
67.0
Deg
F
Heater 40.0
60.0
Deg
F
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
System Pressure
48.0 52.0 50.0 PSI
Outlet Pressure
1.0
30.0
20.0
PSI