6.5.22
Set the Outlet Pressure:
6.5.22.1
Close the front panel.
6.5.22.2
Loosen the Outlet
Pressure Regulator
Locknut.
6.5.22.3
Turn knob until
Outlet Pressure (
OUTP
)
reading is at the desired
setting.
6.5.22.4
Tighten nut to lock.
6.5.23
Check for air leaks:
NOTE:
This is a general procedure that can be applied to any fitting or hose
that has air pressure in it.
DO NOT SOAP TEST THE HUMIDITY
SENSOR. DAMAGE TO THE SENSOR MAY OCCUR.
With Compressor NOT running:
6.5.23.1
Listen for any ‘hissing’ sounds which may indicate a fitting or hose
air leak.