PUREGAS, LLC
P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 38 of 79
P012649 – Rev B
9.6 Testing Consistent Heatless Dryer Cycling
With the Compressor running
:
9.6.1
Open Front Door (section 8.4.1).
9.6.2
Open Front Panel (section 8.4.2).
9.6.3
Locate the Heatless Dryer
and remove Mufflers.
9.6.4
Place your hand beneath the
purge fittings to feel for
purging air. Air should:
Purge from Tower 1 side
30 Seconds
later
Purge from Tower 2 side
30 Seconds
later
Purge from Tower 1 side
30 Seconds
later
…and so on.