![Puregas P4200PM User Manual Download Page 55](http://html1.mh-extra.com/html/puregas/p4200pm/p4200pm_user-manual_1627325055.webp)
PUREGAS, LLC
P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 55 of 79
P012649 – Rev B
10.2 Six Month Maintenance
MODEL:
P4200PM / P5000PM
LOCATION
NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Months)
Procedure
Section 6 12 18 24 30
Install 6 Month Maintenance Kit
P4200PM
- P012907
P5000PM
- P012879
11.7
Install Compressor Maintenance Kit
P4200PM -
P010491
P5000PM -
P3865
11.7
Install Heatless Dryer Maintenance Kit
P200499S
11.7
Read & Record Flow Rate (
FLOW
)
11.1
Measure & Record
Compressor Amp Draw
9.2
Measure & Record Incoming Voltage
(must be 110-125 VAC)
9.4
Test Low Outlet Pressure Alarm
9.15
Set System Pressure (50 PSI)
8.7
Set Outlet Pressure
8.8
Test Consistent Heatless Dryer Cycling
9.6
Test Fan
9.9
Test Cabinet Heater
9.10
Test Compressor ON/OFF Cycling
9.11
Test Compressor Excessive Run Time Alarm
9.12
Test Humidity Alarm & System Shutdown
9.13& 9.14
Test Air Fittings for Leaks
9.16
Clean Precooler Coils
11.5
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
6.5.3
Maintenance Performed by:
Date of Maintenance:
NOTE:
COPY OR PRINT THIS PAGE AND KEEP IT WITH THE AIR DRYER