Pure Cold INSPIRATION2 Installation, Maintenance Manual 2022 | Issue Date: AUG 2022 REV 1
It is the contractor
’
s responsibility to install fixtures according
to local construction and health codes
To allow the oil in the Compressor to settle it is recommended that the
case is not switched on at the Disconnect Switch until at least 90
minutes after the cabinet has been moved. If the cabinet has been laid down
into a horizontal position (or an angle of > 15° from vertical), this period
should be extended to 18 hours
Untie electrical flex and place it in such a location so that it can be connected
to the appropriately rated socket once the case has been moved to the cor-
rect location
As a precautionary measure, be sure to check that there has been no obvi-
ous damage to the refrigeration system in transit.
A recommended inspection on all welded and fastened connections is
a good work practice.
Ensure that the drain is correctly connected and directing water into
the Evaporative Tray (when the Refrigeration Tray is closed) to stop any po-
tential leakage
Summary of Contents for 2CSMA1
Page 2: ...2 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...
Page 5: ...5 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...
Page 6: ...6 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...
Page 23: ...23 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...
Page 26: ...26 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...
Page 31: ...31 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...
Page 40: ...40 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...