Pure Cold INSPIRATION2 Installation, Maintenance Manual 2022 | Issue Date: AUG 2022 REV 1

 

 

T

his booklet is intended for use by owners, end

-

users, installation, and service technicians of Pure Cold 

self

-

contained display cases. The information is provided for the purpose of ensuring the safe and prop-

er use of the equipment. As with all work, it is incumbent upon the owners, end

-

users, installation, and 

service technicians to ensure that suitable and sufficient risk assessments are undertaken prior to any 
work, and that persons are suitably competent to interpret the information provided and undertake 
such work. A properly qualified EPA Technician shall be the only allowed person to access the refrigera-
tion system to fill out the start up sheet as these are critically charged.

 

All components should only be replaced with identical ones all of which are available from Pure Cold Inc

 

All information and diagrams contained within this manual are correct at the time of issue (stated on the 
cover page).

 

Pure Cold Inc. reserves the right to change case specifications or information at any time without notice.

 

 

 

Throughout this manual symbols are used to help draw attention to important facts, procedures and 
warnings. These may vary from simple cleaning procedures to safety warnings, which must be adhered 
to at all times.

 

  No: 

Indicates an incorrect procedure that should not to be carried out

 

   

Yes: 

Indicates the correct procedure, which should be followed.

 

  Stop: 

Indicates a sequence of steps, which must be carried out prior to the final procedure.

 

    

Important Information: 

Indicates information on general procedures.

 

Caution: 

Indicates a potentially hazardous situation, which if not avoided, may result in mi-

nor or moderate injury or property damage only.

 

Electrical Shock / Electrocution: 

Indicates a potential to be electrocuted, which if 

correct procedures are not adhered to, may result in serious injury and or death.

 

 

Summary of Contents for 2CSMA1

Page 1: ...1 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 Purecold Incorporated...

Page 2: ...2 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 3: ...lity for safe arrival If damaged claim must be made to the carrier Apparent Loss or Damage If there is an obvious loss or damage it must be noted on the freight bill or express receipt and signed by t...

Page 4: ...e available from Pure Cold Inc All information and diagrams contained within this manual are correct at the time of issue stated on the cover page Pure Cold Inc reserves the right to change case speci...

Page 5: ...5 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 6: ...6 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 7: ...7 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 Case Lengths 4 48 1220 mm 6 72 1828 mm 8 96 2438 mm Allow 12 16 30mm per endcap...

Page 8: ...self evaporative tray may not manage the amount of water being produced and may overflow For California businesses This product may contain chemicals known to the State of California to cause cancer b...

Page 9: ...her over the top of the cabinet into the store or if there it is large enough into the ceiling void The finished backs on these cases and oversized end caps ensure adequate air flow spac ing Icon fixt...

Page 10: ...Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 TOOLS Forklift 10mm 13mm 16mm Sockets 10mm 16mm 24mm Wrench Impact Drill J Bar Construction Knife Phillips Bits Hacksaw Allen Wrench Set...

Page 11: ...uld only be done by pre determined fork lift slots at rear of case Caution lifting from the underside of the cabinet may cause significant damage Extreme care should be taken to avoid damage to refrig...

Page 12: ...te AUG 2022 REV 1 Carefully remove clear wrapping and bubble panels from fixture ex terior using knife Remove shipping brackets located on top of fixture with 7 16 socket Remove shipping ver tical shi...

Page 13: ...n screw 4 Tighten screw through square opening repeat on other end 5 View of Air Guide attached correctly Air Guides help keep the drywall from being affected by cool stagnant air experienced in all M...

Page 14: ...art with endcap Fixtures are fitted with permanent castors for pushing fixtures into final position Leveling Bolts should be wound down upon final positioning of fixture with 24mm open end wrench Icon...

Page 15: ...and foam tape are provided as part of the installation kit It is highly recommended to seal a case prior to installing another case along side Attach the foam rubber to the ends of the openings shown...

Page 16: ...tion Insert case to case system divider Move the required case tightly against the line up case Insert all necessary joining 7 bolts as indicated in the illustration on the left and finger tighten Pro...

Page 17: ...NSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 A canopy to canopy cover strip and screws are supplied in the case to case fixing kit to ensure a flush and aligned finish to...

Page 18: ...ion Maintenance Manual 2022 Issue Date AUG 2022 REV 1 Fit Kickplate Fits magnetically to circular magnets located to front of wheel and feet assembly Plastic washer to metal kickplate to be at the bot...

Page 19: ...19 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 Front Panels Fitted Lift upwards onto slots...

Page 20: ...corner caps supplied for endcap line up Locate back mounting bracket and rounded cover plate Find slot on front lower panel to snap mounting bracket Secure mounting bracket with Phillips self tapping...

Page 21: ...te AUG 2022 REV 1 Five Shelf Tiered Profile Bay 1 Ticket Rail provided which slides onto shelf front molding before inserting into case Shelves to be 0 degree horizontally fitted The thermometer provi...

Page 22: ...22 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 Locate Brackets on Gable Ends See Floor Bolt Diagram on Next Step...

Page 23: ...23 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 24: ...24 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1 Seismic Brackets Location...

Page 25: ...tringle brace to each rectangle panel Re peat with other panel and triangle brace Place assemblies in dividually on top of seam where cases are joined together Attach each brace end panel with screws...

Page 26: ...26 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 27: ...l position or an angle of 15 from vertical this period should be extended to 18 hours Untie electrical flex and place it in such a location so that it can be connected to the appropriately rated socke...

Page 28: ...left hand side Outlet box for unit requires a requires a 115 208V 60Hz 4 wire grounded connection Mounting of outlet box requires a rigid and secure support for NEMA twist lock plug Per NEC 314 23 gu...

Page 29: ...uge Up to 3 voltage drop is acceptable assume no homeruns are longer than 400 foot Purecold Inspiration 2 Inspiration 2 Low Profile 4 foot 48 case requires minimum 10 gauge on all homeruns over 350 fe...

Page 30: ...022 Issue Date AUG 2022 REV 1 Retaining Bolt for Slide Out Tray Isolater Switch Lift Off Front Panel Dust Debris Filter Slide Out Tray to Condensing Unit and Evaporative Tray Slide Out Tray For Electr...

Page 31: ...31 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 32: ...22 Issue Date AUG 2022 REV 1 The standard refrigerant for the ICON6 case is R448a unless otherwise specified Check the serial plate located on case ceiling plate right hand side for information For ad...

Page 33: ...sue Date AUG 2022 REV 1 Please refer to engineering cut sheet for energy data and total heat rejection values and refrigerant charge sizes Case controllers are pre programmed prior to dispatch Please...

Page 34: ...f Mounting Do not load individual shelves with more than 200lbs Loading of Merchandise Where marked do not fill case beyond the load line label Always allow air space between the product and the shelf...

Page 35: ...handle at the top opening of the case 2 Take a firm grip to the handle and gen tly pull curtain down ward 3 Once at bottom of opening hook han dle to the edge of the opening To Raise Curtain Grip han...

Page 36: ...lified personnel should carry out this process When cleaning cases only use non abrasive odorless detergent cleaner suitable for food hygiene envi ronments diluted to the manufacturers recommended con...

Page 37: ...oks and place flat on the ground 2 Remove mesh screen filter by lifting out of notched panel 3 Rinse filter with water from a medium pressure hose or sink 4 Gently dry filter with soft cloth DO NOT HI...

Page 38: ...ssure water hoses Do not use abrasive and or solvent cleaners that could scratch or irreversibly damage the surface finish Never use a cleaning or sanitizing solution that has an oil base these will d...

Page 39: ...circuits Ensure all fans valves lights blinds and controls are working correctly Check condenser for damage Check evaporator coil for damage Ensure that there are no refrigerant leaks Check drainage...

Page 40: ...40 Pure Cold INSPIRATION2 Installation Maintenance Manual 2022 Issue Date AUG 2022 REV 1...

Page 41: ...be a residual charge Unscrew 4 screws and slide out tray When working with the electric box ensure no strain is placed on connecting cables Refrigeration Tray Electrical Tray General Cautions The cas...