PureAire Monitoring Systems, Inc.
5
1.2.5 Transmitter Interior
1.
Main Power Terminal Block
— This terminal block is where the main
power and 4-20mA analog output connection is made.
2.
Sensor Cell Connector —
This connector is where the Oxygen sensor
cell is connected.
NOTE:
Never connect the oxygen sensor to this
connector while the monitor is powered. This will damage the
oxygen sensor
3.
PTC Resettable Fuse
— The PCB is protected with a PTC Fuse that is
resettable and Never needs to be replaced. If it trips, you will need to
turn power off to the monitor. When power resumes the fuse will reset.
1.2.8 Enclosure Mounting Feet
1. Power and
analog output
Terminal
PTC Resettable
Fuse
Common
Common
mA output
+ 24 VDC
+ 24 VDC
Identification legend
Mounting Feet
Can be oriented
in any direction
Feet can also be
removed for
mounting the O
2
monitor flush
with a wall or
other surface
2. Sensor cell
connector