1. Lamp Life Remaining (days):

The controller tracks the number of days of operation of the lamp and the controller. The default screen will display the
total lamp life remaining (in days). The controller will count down the number of days remaining until the lamp requires
changing (365 days to 1 day). At “0” days, the controller will display [  

A3

] on the display and supply an intermittent audi-

ble chirp (1 second on, 5 seconds off). indicating the need to change the lamp.

DEFERRAL

- Once the “A3” or end of lamp life message is shown on the LED screen, the audible alarm can be deferred

up to 4 separate times. The delay switch is designed to allow you time to address the alarm while you obtain a new UV
lamp. This can be done by simply depressing the push-button “RESET” switch, which is located on the left side of the
controller. Each time the reset switch is pressed the controller alarm is deferred seven days. Once the final 7 day deferral
has been reached, the alarm can be silenced by changing the UV lamp and manually resetting the controller time. To do
this, please follow the step by step instructions below:

RESETTING LAMP LIFE:

a) Disconnect power supply from the controller.
b) Remove expired lamp from the reactor chamber (refer to www.lamprecycle.org for lamp disposal).
c) Install new UV lamp and connect it to lamp connector (refer to page 5).
d) Replace lamp connector.
e) Hold down the “RESET” switch while reapplying power to the controller until you see “rSEt”, then release.
f) 5 second delay will occur until you hear an audible tone & LED display will read [  

365

] once again.

Once you hear the tone, let go of the switch and the counter will be reset. Even though the alarm on the system can be
deferred for a period of time, it is important to address each and every alarm condition as they are indicating that there is
a potential problem with the system and should be remedied.

2. Total days of operation:

The controller also displays the total running time of the controller. To obtain this reading, press the push-button SWITCH
once. The total running time of the controller will be numerically displayed in days. This information will remain displayed
for ten seconds and will then revert back to lamp life remaining default screen. It should be noted that this value cannot
be reset.

3. Lamp failure (blank screen):

When the system recognizes LAMP FAILURE (no current running through the lamp), the 4-segment display will be blank
(no default LAMP LIFE REMAINING screen) and the system will supply an intermittent audible tone (1 second on, 1 sec-
ond off). The system will remain in this state until the condition is remedied.

7

365

1680

Electronic Control Box Operation – UVSS Models

Summary of Contents for UVSS-10

Page 1: ...INSTALLATION MANUAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System UVSS 6 UVSS 10 UVSS 15 UVSS 6M UVSS 10M UVSS 15M 51975 Rev 10 08 ...

Page 2: ...ywhere in the world It has been designed with you the consumer in mind PURA products are lightweight easy to use and simple to maintain PURA products will pro vide you with healthy clean drinking water for years to come What is Ultraviolet Ultraviolet UV light from the sun has long been known for its ability to destroy microorganisms However it has only been in recent years that equipment producin...

Page 3: ...ded see Figure 1D The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination see page 4 For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor use only do not install disinfection sys...

Page 4: ... water matches the flow direction as indicated on the flow restrictor Figure 1C DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 4 Mount the controller horizontally on the wall near the reactor chamber Ideally place the controller above the reactor and away from any water connection point to prevent any water from potentially leaking onto the controller ...

Page 5: ...of this water is not advised due to the extremely high concentration of chlo rine It is important to remember that in the event that a UV is briefly shut down for routine cleaning or during power interruptions where water could have passed through the system the aforementioned procedure must also be fol lowed Note A The addition of chlorine bleach to a hot water tank that has in the past been fed ...

Page 6: ...the inside of the quartz sleeve causing the sleeve to fracture 3 To install a new lamp first remove the lamp from its protective pack aging again being careful not to touch the lamp glass itself Carefully insert the lamp into the reactor vessel actually inside the quartz sleeve Figure 2C Insert the lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber Next at...

Page 7: ...ning UVSS M Models Only CAUTION The UV sensor is a very delicate instrument Extreme care is required when handling and cleaning The sensor window itself is constructed from quartz which is extremely fragile be careful you do not chip or break this quartz window Manufacturer s warranty does not cover damage due to neglect or misuse Mineral deposits and sediment may accumulate on the sensor window d...

Page 8: ... lamprecycle org for lamp disposal c Install new UV lamp and connect it to lamp connector refer to page 5 d Replace lamp connector e Hold down the RESET switch while reapplying power to the controller until you see rSEt then release f 5 second delay will occur until you hear an audible tone LED display will read 365 once again Once you hear the tone let go of the switch and the counter will be res...

Page 9: ...s the push button RESET switch and hold for five seconds This will mute the audible alarm condition for 12 hours CAUTION This advanced warning system has been installed to provide you with the optimum protection against microbiological contamination of you water DO NOT DISREGARD THE WARNING SIGNALS The best way to ensure optimum UV performance is to have the water microbiologically tested by a rec...

Page 10: ...g AC power flowing to the normally closed solenoid valve The valve will remain closed no power until the UV level rises above 49 at which time the solenoid will open allowing for water to pass through To temporarily defer the operation of this solenoid output for up to 12 hours please refer to the instructions outlined on page 8 of this manual NOTE DURING BYPASS the water should NOT be consumed un...

Page 11: ...3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient temper ature 4 Water Appears Milky A Caused by air in the water lines A Run water until air is purged 5 Unit Leaking Water A Problem with o ring seal on gland nut and or UV sensor B Condensation on reactor chamber caused by excessive humidity and cold water C Inadequate inlet outlet p...

Page 12: ... 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 11 Connector 4 pin 89072 Solenoid Valve optional 3 4 120V Solenoid Valve optional 1 120V Solenoid Valve optional 3 4 230V Solenoid Valve optional 1 230V 89528 89529 ...

Page 13: ...Models Alternate Powercords Available 3 4 NPT Outlet 1 NPT on UVSS 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 Connector 4 pin 89072 ...

Page 14: ...dealer the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a...

Reviews: