Conditions For Use

Water quality is extremely important for the optimum performance of your UV system. The following levels are recommend-
ed for installation:

If your water chemistry contains levels in excess of those mentioned above, proper pre-treatment is recommended to cor-
rect these water problems prior to the installation of your UV disinfection system. These water quality parameters can be
tested by your local dealer, or by most private analytical laboratories.

Proper pre-treatment is essential for the UV dis-

infection system to operate as intended.

Installing Your UV Disinfection System

CAUTION

Electronic ballast must be connected to a grounded receptacle and the lamp connector ground wire connected to the stain-
less steel reactor chamber.
• The disinfection system is designed to be mounted either horizontally or vertically at the point-of-use or point-of-entry

depending on the specific flow rate of the unit.
Note: The ideal installation is vertical with the lamp connector at the top. This is to prevent water damage from occur-
ring on the lamp pins and lamp connector.

• The ballast should be mounted either above or beside the reactor chamber. Never mount vertically with AC connector

at top of ballast to prevent moisture from running down cordage and causing a potential fire hazard. Drip loops in all
cordage connected to ballast controller is highly recommended (see Figure 1D).

• The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing

with chlorine (household bleach) to destroy any residual contamination (see page 4).

• For safety purposes, the disinfection system should be connected to a ground fault interrupt circuit.
• The disinfection system is intended for indoor use only, do not install disinfection system where it may be exposed to

the outdoor weather.

• Install the disinfection system on cold water line only.
• If treating the entire house, install the disinfection system before any branch lines.
• A 5 micron sediment filter must precede the disinfection system. Ideally, the disinfection system should be the last

treatment the water receives before it reaches the faucet.

2

Note: The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To
ensure continuous protection, replace the UV lamp annually.

Typical Installation

Figure 1

- Typical installation of disinfection system and the related components that may be used for the installation

Iron (Fe)

< 0.3 ppm (0.3 mg/L)

Hardness*

< 7 gpg (120 mg/L)

Turbidity

< 1.0 NTU

Manganese (Mn)

< 0.05 ppm (0.05 mg/L)

Tannins

< 0.1 ppm (0,1 mg/L)

UV Transmittance

> 75%**

*Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz

sleeve is cleaned periodically. If total hardness exceeds 7 gpg, the water should be softened.

**Call customer service for recommendations on applications where UVT < 75%.

5 micron

Sediment

Filtration

Bypass
Assembly

Hot water distribution

Cold water distribution

Summary of Contents for UVSS-10

Page 1: ...INSTALLATION MANUAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System UVSS 6 UVSS 10 UVSS 15 UVSS 6M UVSS 10M UVSS 15M 51975 Rev 10 08 ...

Page 2: ...ywhere in the world It has been designed with you the consumer in mind PURA products are lightweight easy to use and simple to maintain PURA products will pro vide you with healthy clean drinking water for years to come What is Ultraviolet Ultraviolet UV light from the sun has long been known for its ability to destroy microorganisms However it has only been in recent years that equipment producin...

Page 3: ...ded see Figure 1D The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination see page 4 For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor use only do not install disinfection sys...

Page 4: ... water matches the flow direction as indicated on the flow restrictor Figure 1C DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 4 Mount the controller horizontally on the wall near the reactor chamber Ideally place the controller above the reactor and away from any water connection point to prevent any water from potentially leaking onto the controller ...

Page 5: ...of this water is not advised due to the extremely high concentration of chlo rine It is important to remember that in the event that a UV is briefly shut down for routine cleaning or during power interruptions where water could have passed through the system the aforementioned procedure must also be fol lowed Note A The addition of chlorine bleach to a hot water tank that has in the past been fed ...

Page 6: ...the inside of the quartz sleeve causing the sleeve to fracture 3 To install a new lamp first remove the lamp from its protective pack aging again being careful not to touch the lamp glass itself Carefully insert the lamp into the reactor vessel actually inside the quartz sleeve Figure 2C Insert the lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber Next at...

Page 7: ...ning UVSS M Models Only CAUTION The UV sensor is a very delicate instrument Extreme care is required when handling and cleaning The sensor window itself is constructed from quartz which is extremely fragile be careful you do not chip or break this quartz window Manufacturer s warranty does not cover damage due to neglect or misuse Mineral deposits and sediment may accumulate on the sensor window d...

Page 8: ... lamprecycle org for lamp disposal c Install new UV lamp and connect it to lamp connector refer to page 5 d Replace lamp connector e Hold down the RESET switch while reapplying power to the controller until you see rSEt then release f 5 second delay will occur until you hear an audible tone LED display will read 365 once again Once you hear the tone let go of the switch and the counter will be res...

Page 9: ...s the push button RESET switch and hold for five seconds This will mute the audible alarm condition for 12 hours CAUTION This advanced warning system has been installed to provide you with the optimum protection against microbiological contamination of you water DO NOT DISREGARD THE WARNING SIGNALS The best way to ensure optimum UV performance is to have the water microbiologically tested by a rec...

Page 10: ...g AC power flowing to the normally closed solenoid valve The valve will remain closed no power until the UV level rises above 49 at which time the solenoid will open allowing for water to pass through To temporarily defer the operation of this solenoid output for up to 12 hours please refer to the instructions outlined on page 8 of this manual NOTE DURING BYPASS the water should NOT be consumed un...

Page 11: ...3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient temper ature 4 Water Appears Milky A Caused by air in the water lines A Run water until air is purged 5 Unit Leaking Water A Problem with o ring seal on gland nut and or UV sensor B Condensation on reactor chamber caused by excessive humidity and cold water C Inadequate inlet outlet p...

Page 12: ... 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 11 Connector 4 pin 89072 Solenoid Valve optional 3 4 120V Solenoid Valve optional 1 120V Solenoid Valve optional 3 4 230V Solenoid Valve optional 1 230V 89528 89529 ...

Page 13: ...Models Alternate Powercords Available 3 4 NPT Outlet 1 NPT on UVSS 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 Connector 4 pin 89072 ...

Page 14: ...dealer the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a...

Reviews: