Safety Instructions

WARNING

To guard against injury, basic safety precautions should be observed, including the following:

1. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

2. 

CAUTION

- Always disconnect power before servicing.

3. 

DANGER

- To avoid possible electric shock, special care should be taken since water is present near electrical equip-

ment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting
sections, do not attempt repairs by yourself, refer to an authorized service facility.

4.  Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not

intended to be wet such as, the ballast or lamp connector.

5.  Do not operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped

or damaged in any manner.

6.  Always disconnect water flow and unplug the disinfection system before performing any cleaning or maintenance activ-

ities. Never yank the cord to remove from an outlet; grasp the wall plug and pull to disconnect.

7.  Do not use this disinfection system for other than intended use (potable water applications). The use of attachments

not recommended or sold by the manufacturer/distributor may cause an unsafe condition.

8.  Intended for indoor use only. Do not install this disinfection system where it will be exposed to the weather or to tem-

peratures below freezing. Do not store this disinfection system where it will be exposed to the weather or to tempera-
tures below freezing unless all water has been drained from it and the water supply has been disconnected.

9.  Read and observe all the important notices and warnings on the water disinfection system.
10.  If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less Amperes or Watts

than the disinfection system rating may overheat. Care should be taken to arrange the cord so that it will not be tripped
over or pulled. Circuit breaker must not exceed power cord current rating (ie - 15A for North American NEMA 5-15P). 

11.  SAVE THESE INSTRUCTIONS

WARNING:

The UV light given off by this unit can cause serious burns to unprotected eyes and skin. Never look directly

at an illuminated UV lamp. When performing any work on the UV disinfection system always unplug the unit first. Never
operate the UV system while the UV lamp is outside of the UV chamber.

You  have  purchased  one  of  the  most  technologically
advanced  Ultraviolet  Water Treatment  System  available
anywhere in the world. It has been designed with you, the
consumer, in mind. PURA

®

products are lightweight, easy

to use, and simple to maintain. PURA products will pro-
vide  you  with  healthy,  clean  drinking  water  for  years  to
come.

What is Ultraviolet?

Ultraviolet (UV) light from the sun has long been known
for its ability to destroy microorganisms. However, it has
only been in recent years that equipment producing UV
light has been manufactured for residential use. 

UV  energy  is  produced  by  low-pressure  mercury  vapor
enclosed in a tubular lamp. While a UV lamp resembles a
standard fluorescent lamp, it is similar in appearance only.

Energy  produced  by  the  UV  lamp  has  the  ability  to
destroy microorganisms that can live in water. There are
five major groups of microorganisms that are altered by a

specific  spectrum  of  ultraviolet  light:  viruses,  bacteria,
fungi, algae, and protozoa.

When these microbes are exposed to the proper amount
of UV energy, their DNA structure is scrambled, and they
are unable to reproduce. Since the cell is now sterile or
dead, it is no longer a threat.

PURA Systems

PURA recommends  that  all  UV  systems  include  pre-fil-
ters to process the water before it reaches the UV lamp.
This will ensure that maximum UV exposure is achieved.

PURA Ultraviolet Water Treatment Systems are designed
for indoor use only.

PURA Systems are designed to provide complete water
treatment in a compact, easy-to-use package. Please fol-
low  the  directions  in  this  Guide  exactly  when  installing
your PURA System to ensure that it operates correctly.

Specifications

Item #

Model#

Flow Rate** 

Flow Rate** 

Flow Rate**

Power  

Lamp 

Inlet/ 

UV Chamber Size  

Control Box Size 

Weight 

@ 16 mJ/cm

2

@ 30 mJ/cm

2

@ 40 mJ/cm

2

Consumption Watts

Outlet

(D x L)

(L x W x H) 

lbs (kg)

usgpm (L/min) usgpm (L/min)

usgpm (L/min)

Watts

Size

inches (cm)

inches (cm)

8750

UVSS-6

11 (41.63)

6 (22.71)

4.5 (17)

30

25

3/4" NPT 2.5"(6.35) x 22.07"(57.6) 7.3"(18.54) x 3.15"(8) x 2.52"(6.4)

7 (3.18)

8751

UVSS-10

20 (75.7)

10 (37.85)

7.7 (29.14)

46

37

3/4" NPT 2.5"(6.35) x 35.7"(90.6) 7.3"(18.54) x 3.15"(8) x 2.52"(6.4)

11 (5)

8752

UVSS-15

29 (109.76)

15 (56.77)

11 (41.63)

48

39

1" NPT

3.5"(8.9) x 38.1"(96.7)

7.3"(18.54) x 3.15"(8) x 2.52"(6.4) 14 (6.36)

8753

UVSS-6M

11 (41.63)

6 (22.71)

4.5 (17)

30

25

3/4" NPT 2.5"(6.35) x 22.07"(57.6)

8.3"(21) x 3.15"(8) x 2.52"(6.4)

8 (3.63)

8754

UVSS-10M

20 (75.7)

10 (37.85)

7.7 (29.14)

46

37

3/4" NPT 2.5"(6.35) x 35.7"(90.6)

8.3"(21) x 3.15"(8) x 2.52"(6.4)

12 (5.45)

8755

UVSS-15M

29 (109.76)

15 (56.77)

11 (41.63)

48

39

1" NPT

3.5"(8.9) x 38.1"(96.7)

8.3"(21) x 3.15"(8) x 2.52"(6.4)

15 (6.81)

1

*Flow rates stated at 96% UVDEOL. The manufacturer reserves the right to make product improvements which may deviate from the specifications and
descriptions stated herein, without obligation to change previously manufactured products or to note the change.

Summary of Contents for UVSS-10

Page 1: ...INSTALLATION MANUAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System UVSS 6 UVSS 10 UVSS 15 UVSS 6M UVSS 10M UVSS 15M 51975 Rev 10 08 ...

Page 2: ...ywhere in the world It has been designed with you the consumer in mind PURA products are lightweight easy to use and simple to maintain PURA products will pro vide you with healthy clean drinking water for years to come What is Ultraviolet Ultraviolet UV light from the sun has long been known for its ability to destroy microorganisms However it has only been in recent years that equipment producin...

Page 3: ...ded see Figure 1D The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination see page 4 For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor use only do not install disinfection sys...

Page 4: ... water matches the flow direction as indicated on the flow restrictor Figure 1C DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 4 Mount the controller horizontally on the wall near the reactor chamber Ideally place the controller above the reactor and away from any water connection point to prevent any water from potentially leaking onto the controller ...

Page 5: ...of this water is not advised due to the extremely high concentration of chlo rine It is important to remember that in the event that a UV is briefly shut down for routine cleaning or during power interruptions where water could have passed through the system the aforementioned procedure must also be fol lowed Note A The addition of chlorine bleach to a hot water tank that has in the past been fed ...

Page 6: ...the inside of the quartz sleeve causing the sleeve to fracture 3 To install a new lamp first remove the lamp from its protective pack aging again being careful not to touch the lamp glass itself Carefully insert the lamp into the reactor vessel actually inside the quartz sleeve Figure 2C Insert the lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber Next at...

Page 7: ...ning UVSS M Models Only CAUTION The UV sensor is a very delicate instrument Extreme care is required when handling and cleaning The sensor window itself is constructed from quartz which is extremely fragile be careful you do not chip or break this quartz window Manufacturer s warranty does not cover damage due to neglect or misuse Mineral deposits and sediment may accumulate on the sensor window d...

Page 8: ... lamprecycle org for lamp disposal c Install new UV lamp and connect it to lamp connector refer to page 5 d Replace lamp connector e Hold down the RESET switch while reapplying power to the controller until you see rSEt then release f 5 second delay will occur until you hear an audible tone LED display will read 365 once again Once you hear the tone let go of the switch and the counter will be res...

Page 9: ...s the push button RESET switch and hold for five seconds This will mute the audible alarm condition for 12 hours CAUTION This advanced warning system has been installed to provide you with the optimum protection against microbiological contamination of you water DO NOT DISREGARD THE WARNING SIGNALS The best way to ensure optimum UV performance is to have the water microbiologically tested by a rec...

Page 10: ...g AC power flowing to the normally closed solenoid valve The valve will remain closed no power until the UV level rises above 49 at which time the solenoid will open allowing for water to pass through To temporarily defer the operation of this solenoid output for up to 12 hours please refer to the instructions outlined on page 8 of this manual NOTE DURING BYPASS the water should NOT be consumed un...

Page 11: ...3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient temper ature 4 Water Appears Milky A Caused by air in the water lines A Run water until air is purged 5 Unit Leaking Water A Problem with o ring seal on gland nut and or UV sensor B Condensation on reactor chamber caused by excessive humidity and cold water C Inadequate inlet outlet p...

Page 12: ... 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 11 Connector 4 pin 89072 Solenoid Valve optional 3 4 120V Solenoid Valve optional 1 120V Solenoid Valve optional 3 4 230V Solenoid Valve optional 1 230V 89528 89529 ...

Page 13: ...Models Alternate Powercords Available 3 4 NPT Outlet 1 NPT on UVSS 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 Connector 4 pin 89072 ...

Page 14: ...dealer the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a...